INSTALLATION
25
Attention:
When the oven is placed next to a high
cupboard or another wall made of flammable
material the minimum distance between the
cooker and walls should be at least 50 mm.
The minimum distance between the hotplate
and a cooker hood installed above it should be
at least 650 mm.
If the oven is to be installed in a piece of
kitchen furniture, the minimum space
indicated in fig. 6 must be observed.
If the oven is to be installed between kitchen
cupboards, the panelling of the adjacent
kitchen units must be able to withstand
temperatures of at least 90 °C.
Levelling
The height of the oven can be adjusted with
the adjustable feet (see figure 7).
■ Before using the appliance for the first time
check the connections using water and
washing-up liquid to ensure that there are
no gas leaks.
■ After installation check that the appliance
and the burners are working properly. The
gas flames should be regular and stable
when full on and the burners should not go
out when turned to the lowest setting.
fig. 6
fig. 7
24
INSTALLATION
Installation
General
The fitting of the appliance should only be
carried out by a registered Corgi gas fitter.
The appliance is not connected to the flue gas
outlet channel.
Electrical connection 230 V - 50 Hz.
■ The electrical connection must comply
with national and local regulations.
■ Wall socket and plug must be accessible at
all times.
Gasconnection: RC 1/2˝ (ISO 7/1-RC 1/2)
■ The gas connection must comply with
national and local regulations. Amongst
other things these regulations instruct that:
– only approved materials are to be used.
Attention:
The type of gas and the country for which the
appliance has been designed are indicated on
the ratings plate. The appliance is set in the
factory for G25 (natural gas) with a pressure
of 25 mbar. Appliance category I2L.
■ Connect the oven directly to the mains.
This is because the oven can reach high
temperatures. It can also be connected
with a specially designed gas hose. Attach
this hose at the side of the oven to prevent
it touching any hot parts. A gas tap, which
is easily accessible, should always be used
for the appliance.
Built-in dimensions
fig. 5
front view side view
Table burner information
Combustion with G25 low-setting
Rating nominal
Burner position LA RA RV LV Oven
Burner Semi rapid Semi rapid Simmer Rapid Oven burner
Diameter [mm] 94 94 72 130 120
Flow [l/h] 193,8 193,8 110,7 304,5 310,1
Gas type G25/25mbar G25/25mbar G25/25mbar G25/25mbar G25/25mbar
Rating nominal (kW) 1,75 1,75 1,00 2,75 2,80
Rating minimal (kW) 0,52 0,52 0,30 0,75 1