ELECTRICAL CONNECTION
The heater is designed for permanent connection to a
suitable room thermostat. Please refer to the instructions
of the room thermostat.
ATTENTION: If the power cord of the unit is damaged, it
must be replaced immediately.
Fix mounted thermostats should be mounted next to the
heated room’s entry door at 4’ or 1.3m height from oors.
An alternate location is on an interior wall, not subject to
direct sunlight. The thermostat should not be installed
within 3 feet of the LAVA. Power the thermostat with a
GFCI Protected Circuit.
The device is connected with the supplied connector to
a junction box supplying the AC power supply. If a longer
cable is required, it can be replaced by longer one, 18 AWG
or Larger.
HEATING
The heater is controlled by the externally mounted
thermostat.
GROUNDING
The heater is for use with 120 volts. The green-yellow
grounding of the cord must be connected to a permanent
ground inside the junction box.
Installation and Usage Instruction | LAVA® Design Glass Radiator
8
WIRING DIAGRAM
FOR 120V LAVA® RADIANT PANELS
WITH THE NSPIRE TOUCH THERMOSTAT (UDG4-4999)
Installation Support •(800) 875-5285 • www.WarmlyYours.com
2” x 4” ELECTRICAL BOX
2” x 4” ELECTRICAL BOX
LAVA RADIANT PANEL
BLACK
POWER
SWITCH
15 AMP
120V
BREAKER
Hot Black
Hot
Black
Neutral
White
Neutral
White
GROUND
(green or yellow)
NEUTRAL LOAD
(white or brown)
ELECTRICAL BREAKER PANEL
WHITE
GREEN
BLACK
WHITE
GREEN
HOT LOAD
(black or blue)
CONSULT LOCAL
ELECTRICAL CODE
CONCERNING DESIRED
LAVA MOUNTING LOCATION
NSPIRE TOUCH
PROGRAMMABLE
TOUCHSCREEN THERMOSTAT
(UDG4-4999)
Ground
Fig 9: Connection diagram
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Etherma Lava at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Etherma Lava in the language / languages: English as an attachment in your email.

The manual is 2,19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Etherma Lava

Etherma Lava User Manual - German - 8 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info