Additional functions in connection with CCU
19.5 Minimum setpoint temperature
A minimum setpoint temperature of 4.5°C is set in the
factory settings. The minimum setpoint temperature (4.5
to 25.0°C) can be adjusted via the WebUI.
19.6 Valve error position
If an empty battery has not been recognized, the radia-
tor thermostat moves back into a „valve error position“.
This avoids, that the set temperature in the room incre-
ases due to a low battery. A valve error position of 15 %
is set in the factory settings.
The value can individually
be adjusted (0 to 100 %) via the WebUI.
19.7 Valve offset
If several radiators in one room are operated with a
Homematic Radiator Thermostat some radiators may
heat more than others. In certain cases, some radiators
might be hot while others are still cold. To compensate
this, you can set a valve offset for the radiator that stays
cold. A valve offset of 0% is set in the factory settings.
The value can individually be adjusted (0 to 100 %) via
the WebUI. If the valve is set to
0 % it still closed (re-
gardless of whether the offset function is activated or
not).
96


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for EQ-3 HM-CC-RT-DN Homematic at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of EQ-3 HM-CC-RT-DN Homematic in the language / languages: English, German as an attachment in your email.

The manual is 2,45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info