TOP903H
22. Memorising / Deleting remote controls
22.1 Memorising remote controls via the control panel
22.2 Memorising remote controls from a distance
22.3 Deleting remote controls
22.4 Checking the radio reception level
1. Press the [7] and [5] keys simultaneously for about 1 s. The display flashes .
2. Select the required function with the [7] and [5] keys.
The display indicates
-
Press the required key on the remote control.
The display indicates - for about 1 s, and the remote control is memorised.
The function of the memorised key is:
F0 = OPEN-STOP-CLOSE-STOP
F1 = OPEN-STOP-OPEN-STOP
F2 = CLOSE-STOP-CLOSE-STOP
F3 = STOP
F4 = PARTIAL OPENING
F5 = COURTESY LIGHT ON or RESTART SWITCH-ON TIME
F6 = COURTESY LIGHT ON/OFF
F7 = OPEN
F8 = CLOSE
NB: with automatic closure enabled (parameter b4), the function activates an OPENING
operation and the STOP of the other functions is not permanent.
1. Press the PRG of a previously memorised GOL4 transmitter for 5 seconds
(within the range of the receiver) until the LED lights up.
2. Press any one of the CH keys of the new transmitter.
The new transmitter can memorise the same keys as the existing trans-
mitter.
NB: be careful not to accidentally memorise your neighbours' transmitters.
1. Press the [7] and [5] buttons simultaneously for more than 6 seconds. The display flashes
, first slowly and then more quickly.
All the remote controls are deleted.
PRG
The level of radio reception received can be visualised:
Press the [7] and [5] keys simultaneously for about 1 s. The display flashes .
Press the [7] and [5] keys simultaneously again for about 1 s to see the radio level.
x = 0 no radio signal ... x = 8 high radio level
The visualisation of the radio level is deactivated when the two keys, [7] and [5], are pressed
again for about 1 s.
37


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Entrematic Ditec TOP603H - IP2179 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Entrematic Ditec TOP603H - IP2179 in the language / languages: English as an attachment in your email.

The manual is 2,23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Entrematic Ditec TOP603H - IP2179

Entrematic Ditec TOP603H - IP2179 User Manual - German - 48 pages

Entrematic Ditec TOP603H - IP2179 User Manual - French - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info