7. Electrical connections
NB: the electrical connections and start-up of the FACIL gearmotors are shown in the
VIVAH and E2HFC control panels installation manuals.
i
Before connecting the power supply, make sure the plate data correspond to that of the
mains power supply.
An omnipolar disconnection switch with a contact opening distance of at least 3mm
must be fitted on the mains supply.
Check there is an adequate residual current circuit breaker and overcurrent cutout upstream
of the electrical system.
Use a H05RN-F 3G1.5 type electric cable and connect it to the terminals L (brown), N (blue),
(yellow/green) in the automation.
Secure the cable using a special cable clamp and remove the sheath only where the clamp is.
Connection to the mains power supply (in the section outside the automation) is made on an
independent channel separated from that containing the connections to the control and safety
devices.
The channel must penetrate the automation by at least 50mm via the holes on the base plate.
Make sure there are no sharp edges that may damage the power supply cable.
Make sure the mains power wires (230V) and the accessory wires (24V) are separated.
The cables must be double insulated. Remove their sheaths near the relative connecting ter-
minals, and secure them with cable fasteners (not supplied).
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Entrematic Ditec FACIL - IP2132 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Entrematic Ditec FACIL - IP2132 in the language / languages: English as an attachment in your email.

The manual is 0,65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Entrematic Ditec FACIL - IP2132

Entrematic Ditec FACIL - IP2132 User Manual - German - 20 pages

Entrematic Ditec FACIL - IP2132 User Manual - French - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info