14. Examples of application for automations with
two-way interlocking device without presence
detection
With these settings, command 1-3
starts an opening operation of the
MASTER automation which will close
after the time set with > .
When the delay time set with >
elapses, the SLAVE automation
will open and will close after the time
set with > .
1. Disconnect connectors 1-G1-G3
from the control panels.
2. Set the following parameters on
both automations via the display:
6HWWLQJDGYDQFHGSDUDPHWHUV
>
2”
6HWWLQJLQSXWPRGH
> >
6HWWLQJDXWRPDWLRQSDUDOOHOPRGH
 > >
3. Reconnect connectors 1-G1-G3.
4. Set the radio controls >
>
5. Enable automatic closing >
> on both automations by mak-
ing a jumper for contacts 1-2.
6. Set the desired automatic closing
time ( > )
7. Set the delay time > (from
0 to 30 s).
8. The reservation function >
> can be enabled if a vehicle
arrives from the same direction
while another one is still in transit.
A second opening command is
stored and executed as soon as the
cycle in progress terminates.
UP
DOWN
AUX
ENTER
ESC
016 0 1 1 1
G1 G3
234913520
+LP-
18
RDX
Automatic
external closing
Step-by-step
Partial opening
Opening
Stop
-
+
24V output
Safety stop
Flashing light
Automation
status lamp
UP
DOWN
AUX
ENTER
ESC
016 0 1 1 1
G1 G3
234913520
+LP-
18
RDX
Automatic
external closing
Stop
-
+
24V output
Safety stop
Safety reopening
Safety
reopening
Flashing light
Automation
status lamp
CS12M Master
CS12M Slave
52


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Entrematic Ditec CS12M - IP2163 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Entrematic Ditec CS12M - IP2163 in the language / languages: English as an attachment in your email.

The manual is 1,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Entrematic Ditec CS12M - IP2163

Entrematic Ditec CS12M - IP2163 User Manual - German - 56 pages

Entrematic Ditec CS12M - IP2163 User Manual - French - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info