11. Examples of sliding gate applications
When the CS12M control panel is used for sliding automation applications,
the following connections can be made:
Set
Set
Connect the limit switches to the terminal
Connect the limit switches to the terminal
Set
With these settings, if an obstacle is detected while opening, the door wing stops and performs a
disengagement operation whereas during a closing operation, the door wing reopens.
In this configuration, the door wing stops against its respective mechanical closing and opening
end stop. In the event of obstacle detection before the activation of the proximity limit switch while
opening, the door wing stops, performing a disengagement operation; after the proximity limit
switch is activated, the door wing stops against the obstacle.
In the event of obstacle detection during closing and before the activation of the proximity limit
switch, the door wing reopens; after the proximity limit switch is activated, the door wing stops
against the obstacle.
Example 1 - Door wing stops against mechanical end stops (standard setting)
Example 2 - Door wing stops against limit switches (setting with standard limit switches
installed)
Example 3 - Door wing stops against mechanical end stops and reverses motion if an obstacle
is detected
x2 s
- set the correct opening direction:
x2 s
LSW
LSW
49


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Entrematic Ditec CS12M - IP2163 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Entrematic Ditec CS12M - IP2163 in the language / languages: English as an attachment in your email.

The manual is 1,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Entrematic Ditec CS12M - IP2163

Entrematic Ditec CS12M - IP2163 User Manual - German - 56 pages

Entrematic Ditec CS12M - IP2163 User Manual - French - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info