LACP Timeout
Link Aggregation Control Protocol (LACP) allows
the exchange of information with regard to the link
aggregation between two members of aggregation. The
LACP Time Out value is measured in a periodic interval.
Checkrstwhethertheportinthetrunkgroupisup.
When the interval expires, it will be removed from the
trunk. Set a Short Timeout (one second) for busy trunked
links to ensure that disabled ports are removed from the
trunk group as soon as possible. The default value for
LACP time out is: Long Timeout.
Timeout: Select the administrative LACP timeout.
Long – Long timeout value.
Short – Short timeout value.
Long:
The LACP PDU will be sent for every 30 seconds, and
theLACPtimeoutvalueis90seconds.
Short:
The LACP PDU will be sent every second. The
timeout value is 3 seconds.
Apply: Click APPLY to update the the system settings.
85


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Engenius EWS5912FP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Engenius EWS5912FP in the language / languages: English as an attachment in your email.

The manual is 11,27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Engenius EWS5912FP

Engenius EWS5912FP Installation Guide - English - 3 pages

Engenius EWS5912FP Installation Guide - Dutch - 4 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info