620000
8
Zoom out
Zoom in
Previous page
1/346
Next page
~15~
d.
Press
to enter phonebook when in the Standby mode.
9.
END; On/Off Key (
)
a.
Ends a call.
b. Leaves current menu operation, up one level.
c. Press for 3 seconds to off the power
10.
CALLER ID Key (
)
a.
Review caller ID list.
b. Including received and missed caller ID.
Additional Handset Features
1. Multiple handsets registration
a.
Up to 9 handsets can be registered to a base station
b. ID 11-19: individual Handset IDs.
c. ID 91-99: Group IDs. Handsets can “subscribe” from the handset
menu to group(s) and be paged when a landline caller or an
intercom caller enters a Group ID.
2. Ringer Vibrator
a. Two options for Line (incoming call) ringing & Intercom ringing.
b. Six-level ringer volume selections (Off/Low/Medium/High/Vibrate/
Vibrate & High) for each option.
c.
Eight ringer type selections for each option.
3. Caller ID
Displays incoming call phone number and name on the LCD (needs
Caller ID service from local telephone company)
4. Call waiting with caller ID
Displays 2
nd
incoming call information on the same phone line when 1
st
call is in progress (needs Call Waiting with Caller ID service from local
telephone company)
5. Name tagging with caller ID
Match the caller ID with the phone book entries; once matched, the LCD
screen will display the name or nickname instead of pure caller ID info
(needs Call Waiting with Caller ID service from local telephone
company).
6. DND (Do Not Disturb, i.e., Silent Ring)
~16~
7. Call Logs
a. Redial: Stores 10 phone numbers (up to 26 digits each) dialed most
recently. Can perform last-number redial on all 10 numbers.
b. Received & New Call Log: Total 50 entries (16-digit phone number,
16-character names, and Date/Time stamp), needs Caller ID service
from local telephone company.
c. Phone numbers and names can be saved into phonebook while in
display.
8. Call Barring: Block outgoing call and incoming call.
a. Outgoing call:
a-1. Block the users from dialing long distance calls or international
calls
a-2. Up to 5 digits of each call barring setting; up to 5 entries
allowed.
b. Incoming call:
b-1. PA On/Off: Enable or disable the broadcast from other handsets
or base station. When PA is Off, the handset can’t receive broadcast
from base station or other registered handsets, but it can broadcast
to base station or other registered handsets.
b-2. Line On/Off: Enable or disable the capability to receive incoming
call from telephone line. When Line is Off, the handset can’t receive
incoming call from telephone line, but it can still make outgoing call.
b-3. Int. On/Off: Enable or disable the intercom from other handsets
or base station. When Int. is Off, the handset can’t receive intercom
from base station or other registered handsets, but it can intercom to
base station or other registered handsets.
c.
This changing requires to entering the “Call Settings” (MENU-4-3).
[Note] You need to key in the accurate user ID and password to perform
this feature. The default password is “0000”.
9.
Any Key Answer (except and SILENT Soft Key)
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Engenius EP802 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Engenius EP802 in the language / languages: English, German, Dutch, French, Italian, Polish, Turkish, Spanish as an attachment in your email.

The manual is 21,25 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Engenius EP802

Engenius EP802 Installation Guide - English - 2 pages

Engenius EP802 Installation Guide - Dutch - 2 pages

Engenius EP802 User Manual - Dutch - 31 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info