729077
11
Zoom out
Zoom in
Previous page
1/38
Next page
21
Basic Base Station Features
1.
Antenna
a. The antenna port has a reverse thread connector; to remove antenna or
cable, turn clockwise; to install, turn counterclockwise. Improper
installation may damage the connector
b. When using an outdoor antenna, locate the antenna (not the base
station itself) as high as possible for a clear transmission path.
2.
Audio
-
in Jack
(3.5mm)
3.
Line Status LED
Indicates an active telephone line.
4.
Power
LED
Indicates base station has power.
5.
L1
L4
Standard RJ
-
11C/CA
-
11A connector to plug in the telephone line
6
.
DC In
Jack
Jack
for AC power adapt
e
r
ReThe AC power adapter is 100~240VAC/12VDC, do not use other non-
compatible AC, in case any damage or safety issue.
7
.
Registration
Key
(REG)
Enters registration mode along with handset, assigns handset ID (10-90).
8
.
Reset Button
a.
Restores base station to factory settings
b.
Reset button is indented to prevent accidental system reset.
c. All handsets (including administrator) and additional base(s) need to be
re
-
registered after a base station reset.
9.
Grounding
screw
Connecting with grounding
wire
10.
Console jack
Jack for firmware upgrade (Type
-
B USB connector)
Re:
Please consult with EnGenius Tech support
about the firmware upgrade.
22
Additional Base Station Features
1.
4-channel Auto-Attendant
a.
4 Auto-Attendant can be active at the same time in case of 4
simultaneous incoming calls.
b. Allows private paging to a single handset (with individual Handset ID) or
group paging to a group of handsets (with Group ID).
c.
Per line AA enable/disable by administrator. When disabled for a line,
the administrator can set all handsets to ring with an incoming call on
that line, or a particular Handset/Group ID (either one; not
simultaneously) can be assigned to have incoming call privileges on that
line. See AA Configuration by Administrator
d.
Up to 120 seconds customizable main greeting message.
e.
Default of 4 lines AA is OFF.
2.
Optional Outdoor Antenna Kit with cable.
Administrator Features
Handsets 10 and 11 are designated administrators. Both have the same authority to
perform base station administrative functions from their handset menu selections. No
password is required.
1.
Supports both DTMF and Pulse dialing(For DuraFon PRO
only
)
a. From an administrator handset (Handset 10 or 11 ), press MENU- 9 1
enter base ID(00
07)
-
1
to select Tone or Pulse dialing mode.
b.
Default is
Tone dialing.
2.
Administrator programmable Flash key timing(For DuraFon PRO
only
)
a. From an administrator handset (Handset 10 or 11), press MENU- 9 -1-2 to
select flash key timing
b.
9
-
level (100 ms
-
900 ms) timing selections, default=
6
00 ms
.
c. The default value (600 ms) works in most areas. Changing this setting may
result in Flash function not working. Change only when you are certain
the new value will work.
3.
Call Transfer
to PBX Extension(For DuraFon PRO
o
nly
)
a.
When the DuraFon PRO is installed behind a PBX system, you can pre-
program the feature code of call transfer function.
b.
Need to adjust the Flash time to match your PBX setting.
Re:
If loosing administrator handsets (handset 10 and 11), all settings must be
reset (reset the base and re
-
register all handsets).
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Engenius DuraFon PRO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Engenius DuraFon PRO in the language / languages: English as an attachment in your email.

The manual is 4,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info