MAINTENANCE
ODYSSEY
®
batteries are very different from standard liquid-acid batteries that are
openly vented. The ODYSSEY battery is and operates as a sealed battery, recycling
nearly all gases internally under normal operating conditions. There is no corrosion
of the positive terminal or corrosion to the surrounding area. ODYSSEY batteries
are shipped fully charged from the factory, but prior to installation, check the battery’s
voltage to see if it is 12.65V or greater. If not, recharge it using the procedure below.
Do not charge in an air tight compartment.
Never attempt to remove the top decal cover, as it will cause the battery to fail.
CHARGING
The SOC in an ODYSSEY battery can be determined from the following chart:
ODYSSEY
®
PERFORMANCE SERIES
BATTERIES
Model
Voltage
PHCA**
(5 sec)
CCA* HCA MCA
Nominal Capacity
Reserve
Capacity
Minutes
Length
inches
(mm)
Width
inches
(mm)
Height
inches
(mm)
Weight
lbs
(kg)
Terminal
Torque
Specs in-lbs
(Nm max)
Internal
Resistance
(m
Ω
)
Short
Circuit
Current
(20 Hr
Rate-Ah)
(10 Hr
Rate-Ah)
75/86-705
12 1100 708 875 760 49 45 89
9.46
(240.3)
7.01
(178.1)
7.98
(202.7)
43.4
(19.7)
SAE, Side 3/8-16
"
Receptacle
60
(6.8)
side only
2.8 2200
48-720 12 1250 723 950 842 69 63 130
10.91
(277.1)
6.89
(174.2)
7.5
(190.5)
48
(21.8)
SAE
N/A
2.8 2300
34-790
12 1500 792 1200 990 61 57 124
10.85
(275.6)
6.78
(172.2)
7.91
(200.9)
46.6
(21.1)
SAE
N/A
2.9 2400
34R-790 12 1500 792 1200 990 61 57 124
10.85
(275.6)
6.78
(172.2)
7.91
(200.9)
46.6
(21.1)
SAE
N/A
2.9 2400
34M-790
12
1500 792 1200 990 61 57 124
10.85
(275.6)
6.78
(172.2)
7.93
(201.4)
47.6
(21.6)
SAE and 3/8-16
"
Stud (Pos.), 5/16-
18
" Stud (Neg.)
60
(6.8)
studs only
2.9 2400
78-790
12 1500 792 1200 990 61 57 124
10.85
(275.6)
7.00
(177.8)
7.4
(188.0)
47.1
(21.4)
Side 3/8-16
"
Receptacle
60
(6.8)
2.9 2400
65-760
12 1500 762 1200 891 64 59 129
11.86
(301.2)
7.19
(182.6)
7.38
(187.5)
49.8
(22.6)
SAE N/A 2.3 2500
31-800 12 1600 802 1380 1188 99 94 188
13.0
(330.2)
6.79
(172.5)
9.42
(239.3)
69.0
(31.3)
SAE or 3/8-16" Stud
200
(200.6)
studs only
2.6 2600
31M-800
12 1600 800 1380 1200 99 94 188
13.0
(330.2)
6.79
(172.5)
9.46
(240.3)
69.3
(31.4)
SAE and 3/8-16
"
Stud (Pos.), 5/16-
18
" Stud (Neg.)
60
(6.8)
studs only
2.6 2600
8
Publication No. 2602-0232, Rev AA - September 2016 www.odysseybattery.com
Voltmeter Reading State of Charge
12.84 Volts or higher 100%
12.50 Volts 75%
12.18 Volts 50%
11.88 Volts 25%
*Cold Start Performance S.A.E. J537 June 82
** Pulse Current
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Enersys ODYSSEY EXTREME SERIES BATTERIES at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Enersys ODYSSEY EXTREME SERIES BATTERIES in the language / languages: English as an attachment in your email.

The manual is 1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info