7. Do not use the battery charger unless the battery recommended charge voltage matches the
output voltage rating of the charger.
8. Use of an attachment not recommended or sold by EnerSys
®
Energy Products Inc may
result in a risk of fire, electric shock or injury to persons.
9. To reduce risk of damage to electric plug and cord, pull by plug rather than cord when
disconnecting charger.
10.Extension cords should not be used unless absolutely necessary. Use of an improper
extension cord could result in a risk of fire and electric shock. If an extension cord must be
used make sure:
a. Use only a properly wired extension cord in good electrical condition.
b. Use an industrial grade / heavy duty UL or CSA approved extension cord. Check
extension cord before use for damage, bent prongs, and cuts. Replace if damaged.
Always make your extension cord connection on the charger side first. After connecting
the extension cord to the charger proceed to plug the extension cord into a nearby 120
VAC GFCI protected (Ground Fault Circuit Interrupt) outlet. Below are manufacturer
recommendations for the right size UL or CSA Approved grounded extension cord.
i. Up to 50 feet in length use a 18 AWG extension cord.
ii. 50 to 100 feet in length use a 16 AWG extension cord.
iii. 100 to 150 feet in length use a 14 AWG extension cord.
11. Do not operate charger if any protective AC and DC cable insulation, charging clamps, DC fuse
holders and/or maintainer ring terminals have been damaged or compromised. Return the
charger for service and repair to EnerSys
®
Energy Products Inc immediately.
12. Do not operate the charger if it has received a sharp blow, direct hit of force, been dropped or
otherwise damaged in any way. Return the charger for service and repair to EnerSys
®
Energy
Products Inc immediately.
13. Do not disassemble charger. Incorrect reassembly may result in a risk of electric shock or
fire. If service or repair is required please call EnerSys
®
Energy Products Inc at
1-660-429-2165 between 8:30 am - 5:00 pm Central Standard Time. Unauthorized attempts
to service, repair or modify may result in a risk of electrical shock, fire or explosion and
will void warranty.
14. To reduce risk of electric shock, unplug charger from outlet before attempting any maintenance
or cleaning. Turning off controls will not reduce risk.
15. Do not expose charger to rain or snow.
Important Safety Instructions
3
16. GROUNDING AND AC POWER CORD CONNECTION INSTRUCTIONS
a. Charger should be grounded to reduce risk of electric shock. Charger is equipped with
an electric cord having in equipment-grounding conductor and a grounding plug. The
plug must be plugged into an outlet that is properly installed and grounded in
accordance with all local codes and ordinances.
DANGER
Never alter AC cord or plug provided - If it will not fit outlet, have proper outlet installed by a
qualified electrician. Improper connection can result in a risk of an electric shock.
b. This battery charger is for use on a nominal 120-volt circuit, and has a grounding
plug that looks like the plug illustrated in Figure A. A temporary adapter, which looks
like the adapter illustrated in Figure B may be used to connect this plug to a two-
pole receptacle as shown in Figure B if a properly grounded outlet is not available.
The temporary adapter should be used only until a properly grounded outlet can be
installed by a qualified electrician.
DANGER
Before using adapter as illustrated, be certain that center screw of outlet plate is grounded.
The green-colored rigid ear or leg extending from adapter must be connected to a properly
grounded outlet - make certain it is grounded. If necessary, replace original outlet cover
plate screw with a longer screw that will secure adapter ear or lug to outlet cover plate and
make ground connection to grounded outlet.
Use of an adapter is not allowed in Canada. If a grounding type receptacle is not available,
do not use this appliance until the proper outlet is installed by a qualified electrician.
AC Cord Connections
4
Figure A
Grounding pin
Grounding means
Metal screw
Adapter
Figure B
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Enersys ODYSSEY Battery Charger at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Enersys ODYSSEY Battery Charger in the language / languages: English as an attachment in your email.

The manual is 0,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info