768048
28
Zoom out
Zoom in
Previous page
1/56
Next page
ENGLISH
28
OPERATING
SAFETY NOTES
!
INTENDED USE
QUsing this device in an enclosed area is DANGEROUS
and PROHIBITED.
QCAUTION: For use
outdoors or in well
ventilated areas. In the
case of a well ventilated
area, at least 25 % of
the enclosure area must
be open. The enclosure
area is the total of all walls. According to applicable
regulations, the device must be installed and the
liquid gas cylinder used.
QThe installation area must have a minimum volume
of 20 m³ per 1 kW of installed nominal heat input
of the fire pit and be well ventilated (covered patio,
beer tents, etc.).
QThis device must be installed per these instructions.
QThe fire pit must not be used in residential,
basement and office spaces or similar spaces.
QThe fire pit may only be operated using an
interconnected pressure regulator with a
permissible output pressure (see Type plate and
factory preset).
QOnly use the types of gas and gas cylinders
recommended by the manufacturer!
QThe gas cylinder should be in the designated
enclosure when operating the device.
QCAUTION: The glass becomes very hot during
use. If the screen on the device splits or breaks,
do not touch with bare hands. Immediately shut
off the gas supply, remove all shards with tools to
prevent injuries, and contact the manufacturer for
a replacement screen.
FIRE AND EXPLOSION HAZARD
QThe device must be placed on a level, firm base.
QWe recommend using a suitable mat to protect the
flooring.
QIn high winds, ensure the device does not tip.
Q Verify the gaskets on the cylinder valve are in place
and in good condition (no damage) before every
use. Do not use additional gaskets.
Q Never kind the gas hose.
Q The remaining distance to flammable objects must
not be less than 1 m.
Q Protect liquid gas cylinder from strong sunlight
(< 40°C).
Q Maintain a safe distance to flammable
materials and substances during use. The
distance in the radiation direction between
the radiating surface and flammable
substances must not be less than 2 m.
Q Do not cover the vents of the housing
for the liquid gas cylinder. Any escaping
gas would build in the container, posing an
explosion hazard.
Q Do not move the device during use.
Q Remove the gas cylinder before moving the device.
Q Repairs and maintenance of gas-related parts of the
device must be carried out by authorised specialists.
Q Always immediately shut off the valve of the gas
cylinder if a malfunction occurs.
Q Shut off the valve of the liquid gas cylinder or the
pressure regulator after use.
Q Check the gas hose for cracks and damages before
every use.
Q The hoses must be replaced within the prescribed
periods.
Q The gas hose and the pressure regulator must be
replaced by a specialised company at least every
10 years.
Q If the gas hose is damaged, replace with a gas
hose of the same quality and length, not to exceed
150 cm.
Q Do not use the device if there is a gas leak. The
gas supply must be shut off if this occurs during
use. Check the device and replace damaged parts
before using it again. Tighten any lose connections.
Q Close the valve of the liquid gas cylinder or the
pressure regulator before moving the device.
Q Check all connections for leaks following
installation. Use a foaming agent (e.g. gas control
spray or soapy water).
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Enders Nova 5604 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Enders Nova 5604 in the language / languages: English, German, Spanish as an attachment in your email.

The manual is 2.27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Enders Nova 5604

Enders Nova 5604 User Manual - German - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info