unit of precipitation: mm/inch
radio signal range: to 100 m in open area
number of sensors which can be connected: max. 3 (temperature/humidity/wind sensor), max. 1
(precipitation sensor)
wireless sensor: transmission frequency 433 MHz, 10 mW e.r.p. max.
station power supply: 3× 1.5 V AAA batteries (not included)
adapter AC 230 V/DC 5 V, 300 mA (included)
temperature/humidity/wind sensor power supply: 4× 1.5 V AA (not included)
precipitation sensor power supply: 2× 1.5 V AA (not included)
station dimensions and weight: 17 × 192 × 127 mm, 364 g
temperature/humidity/wind sensor dimensions and weight: 275 × 135 × 310 mm, 377 g (without
batteries)
precipitation sensor dimensions and weight: 100 × 106 × 166 mm, 220 g (without batteries)
Getting Started/Installation
1. Plug the power adapter into the station, then insert batteries rst into the weather station and then
into: wireless temperature/humidity/wind sensor and wireless precipitation sensor. The battery
compartment of the precipitation sensor is protected by screws; use a suitable screwdriver.
2. When inserting the batteries make sure the polarity is correct to avoid damaging the weather
station or sensors. Only use alkaline batteries of the same type; do not use rechargeable batteries.
3. Place all the units next to each other. The weather station will automatically detect the signal
from sensors within 3 minutes. If signal from sensors is not detected, long-press the button
on the weather station to repeat the search and press the TX button on the sensor.
4. To ensure correct measurement, the temperature/humidity/wind sensor and precipitation sensor
must be placed above the ground surface (at least 1.5 m) onto a horizontal surface and outside
of buildings and structures. Both sensors must be rmly screwed on to prevent their damaging.
First, screw the mounting plate onto a level surface, then mount the mounting rod into it. Screw
the temperature/humidity/wind sensor onto the rod. Wind must ow freely around the wind
sensor from all sides. Check that the wind direction indicator and paddles for measuring wind
speed can rotate freely. The north arrow (N) on the built-in compass must point to the real north.
Otherwise, wind direction will always be displayed incorrectly. When choosing a suitable place for
mounting the sensor, check before installation that the main station is within range of the sensors.
The range of the sensors may decrease substantially in areas with large number of obstacles.
5. Do not place the sensors onto metal objects as this will reduce their transmission range.
6. If the low battery icon is displayed, replace batteries in the sensors or weather station.
Changing Channel and Connecting Additional Sensors (Valid for Temperature/
Humidity/Precipitation Sensor)
1. Choose the desired channel 1, 2, or 3 for the sensor by repeatedly pressing the button. Then,
long press the button; the icon will start ashing.
2. Remove the cover from the battery compartment on the rear of the sensor and set the sensor
switch to the desired sensor channel number (1, 2, 3), then insert batteries (4× 1.5 V AA). Data
from the sensor will be loaded within 3 minutes.
3. If sensor signal is not found, remove the batteries and proceed again in accordance with steps
1 and 2 or press the TX button.
Attention:
The anemometer (wind speed and direction measurement) only functions on channel 1 (spare
sensor E06016).
Channels 2 and 3 are used for information about outdoor temperature and humidity (spare sensor
E06018).
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for EMOS SELECT 9001 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of EMOS SELECT 9001 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 2.11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info