GETTING STARTED
WIRELESS SENSOR
1. Remove the battery door.
2. Insert 2 x AA size batteries into the battery compartment. Make sure you insert
them the right way according to the polarity information marked on the battery
compartment.
3. Close the battery door.
Note:
- This wireless sensor can receive the Radio controlled clock signal for main unit auto
time setting. Just pair up the sensor with main unit to apply this function.
- Once the channel is assigned to a Wireless Hygro-Thermo sensor, you can only
change it by removing the batteries or resetting the unit.
- Avoid placing the sensor in direct sunlight, rain or snow.
MAIN UNIT
1. Plug the power adapter to power up the main unit.
2. Once the main unit power up, it will enter normal time mode.
Note:
- You can using AAA batteries for backup purpose, remove the battery door and
install 3 new AAA size batteries as per the polarity information marked on the battery
compartment, then close the battery door.
- If no display appears on the LCD after installing the batteries, press the [ RESET ] key
by using a metal wire.
- To avoid the wireless sensor and main unit pairing fail, please power up the sensor(s)
rst, and then press [ RESET ] key in main unit after sensor setup.
- You may not receive the signal immediately. Due to the atmospheric disturbance, the
best reception often occurs during night time.
WIRELESS SENSOR SIGNAL RECEIVING
1. In normal mode, press [ SENSOR ] key once to start receiving the sensor signal of
current on displaying channel. The signal icon will ash.
For example, when CH 1 is displayed, pressing [ SENSOR ] key will start receive for
CH 1 only.
2. The signal icon will ash until the reception succeeded. If no signal is received within
5 minutes the icon will disappear.
Receiving wireless signal after manual reset or the [
SENSOR ] key is pressed
When waiting for signals, “--” will display in the readings
eld
Good wireless sensor signal
3. If the signal for Ch 1~8 has discontinued and
does not recover within 1 hour, the signal icon
will disappear. The temperature and humidity will
display “Er” for the corresponding channel.
4. If the signal does not recover within 48 hours, the
Er” display will become permanent you need to
replace the batteries of “Er” channel’s sensors and
then press [ SENSOR ] key to pair up the sensors
of each “Er” channels again.
Note:
After replacing the batteries of the wireless sensor or the unit fails to receive wireless
sensor signal of a specied channel. During the failed channel is displaying, press
[ SENSOR ] key to manually receive that sensor signal again.
VIEW CHANNEL OF MULTIPLE WIRELESS SENSORS
1. In normal mode, press [ CHANNEL / + ] key to switch the display between CH 1~8.
2. In normal mode, press and hold [ CHANNEL / + ] key for 2 seconds to enter auto-
cycle mode, after a bi sounds, it will alternately displays the channels at 4 second
intervals.
3. During auto-cycle mode, press [ CHANNEL / + ] key once to stop auto-cycle and
display the current channel.
4. Using auto-cycle mode will only display the communicated channels. For example,
when CH 1 and 6 have received the signal from the corresponding sensor, holding [
CHANNEL / + ] key for 2 seconds will only toggle the readings of CH 1 and 6. Other
channels will be neglected.
CH 1 CH 6 CH 1
RECEPTION OF RADIO CONTROLLED SIGNAL
The time and date are radio-controlled. The current time and date are automatically
synchronized with the signal that transmitted from RC station through wireless sensor.
Please make sure the wireless sensor is connected to the main unit.
RCC SIGNAL STRENGTH INDICATOR
The signal indicator shows signal receive status. Flashing wave segment means RCC
signals are being received. The signal receiving status could be classied into 2 types:
No RCC signal received Received RCC signal
Note:
- Every day the wireless sensor will automatically search for the time signal at 2:00 and
17:00.
- Always place the unit away from interfering sources such as TV set, computer, etc.
- Avoid placing the unit on or next to metal plate.
- Closed area such as airport basement, tower block or factory is not recommended.
- Do not start reception on a moving article such as vehicle or train.
DAYLIGHT SAVING TIME (DST)
This clock has been programmed to automatically switch when the daylight saving time is
in effect. User can disable the DST function in time and calendar setting mode.
Note:
DST AUTO/OFF setting only available when RCC function is ON.
TIME AND CALENDAR SETTING
1. In normal mode, press and hold [ TIME SET ] key for 2 seconds to enter date and
time setting mode.
2. Press [ CHANNEL / + ] or [ MEM / - ] key to adjust the setting.
3. Press [ TIME SET ] key to enter the next setting
4. The setting sequence: 12/24H hour minute second year DM/
MD month day time zone language RCC ON/OFF DST
AUTO / OFF
5. When you complete the setting, press [ TIME SET ] key or leave the unit for 60
seconds to return to normal mode.
Note:
DST AUTO/OFF setting only available when RCC function is ON.
12/24H setting
Hour/Minute/
Second setting
Year setting
Month/Day
setting D/M M/D
Month/day
setting M/ D
Time zone
setting
00H 01H...23H -23H...-01H 00H
Language
setting
EN FR DE ES IT NL RU
RCC setting
DST (day light
saving) setting
ALARM TIME SETTING AND DISPLAY
1. In normal time mode, press and hold [ ALARM ] key for 2 seconds until the alarm
hour digit ashes to enter alarm time setting mode.
2. Press [ CHANNEL / + ] or [ MEM / - ] key to change the value. Press and hold the
key for quick-adjust.
3. Repeat the above operations to set the alarm time in this order: Hour → Minute.
4. When you complete the setting of Minute, Press [ ALARM ] key or leave the unit for
60 seconds to return to normal mode.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for EMOS 5002 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of EMOS 5002 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 6.73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info