3. IMPORTANT INFORMATION
3.5 Part of refrigerant safety table R 32
COOLANT GAS TYPE R 32
GWP 675
Name Difluoromethane 3.0
Indications of dangers
H220: Highly flammable gas.
H280: Contains gas under pressure; may explode if heated.
DESCRIPTION OF FIRST AID MEASURES
Inhalation
In a high concentration it can cause suffocation. The symptoms may include loss of mobility and/or
consciousness. The victims may not realise they are suffocating. Wearing the breathing apparatus,
move the victims to a ventilated area, make them lie down and keep them warm. Call a doctor. Provide
artificial respiration only if the victim is not breathing.
Contact with the eyes:
Rinse the eyes immediately with water. Remove any contact lenses if it is easy to do so. Continue to
rinse. Rinse with plenty of water for at least 15 minutes. Get medical attention immediately. If medical
care is not available immediately, rinse for another 15 minutes.
Contact with the skin: Contact with the evaporating liquid may cause the skin to freeze.
FIRE SAFETY
General fire hazards: Heat may cause the container to explode.
Extinguishing means Sprays or splashes water. Dry powder. Foam.
Inappropriate extinguishing means: Carbon dioxide.
Special hazards arising from the
substance or mixture:
No data available.
Dangerous combustion products:
I
n the event of a fire, the following products may be produced by thermal decomposition: hydrofluoric acid
; carbon monoxide; carbon oxide
; carbonyl difluoride
RECOMMENDATIONS FOR FIRE-FIGHTERS
Special fire fighting procedures:
In the event of a fire: stop the leak if it is not dangerous. Do not extinguish the flames on the leak
because there is the possibility of an uncontrolled explosive re-ignition. Spray continuously with water
from a safe position until the container has cooled down. Use extinguishers to extinguish the fire.
Isolate the source of the fire or let it burn.
MEASURES IN CASE OF ACCIDENTAL ESCAPE
Personal precautions, protective equipment and
procedures in case of an emergency:
Evacuate the area. Ensure suitable ventilation. Assess the risk of potential explosive atmospheres.
Eliminate all sources of ignition if it is not dangerous. Monitor the concentration of the product that has
been released.
Prevent it from seeping into sewers, basements, excavations or areas where accumulation may be
dangerous. Use a breathing apparatus to enter the affected area unless it has been proven that the
atmosphere is breathable. EN 137 Respiratory protective devices - Open-circuit breathing apparatus with
full mask - Requirements, testing, marking.
HANDLING AND STORAGE:
Only suitably trained and experienced people can handle gas under pressure. Use only specific
equipment, suitable for the product, the pressure and the temperature of use.
INDIVIDUAL EXPOSURE/PROTECTION CHECKS
Control parameters
Limit values for professional exposure
No exposure limit has been defined for any component
DNEL values
Critical component Type Value Remarks
difluoromethane Workers - inhalation 7035 Repeated dose toxicity
Systemic, long-term mg/m
3
PNEC values
Critical component Type VAlue Remarks
difluoromethane Aquatic (fresh water) 0,142 mg/l -
Aquatic (intermittent releases) 1,42 mg/l -
Sitting (fresh water)
0,534
mg/kg
-
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Emmeti X-Evo - XX 17X3E R32 Outdoor unit at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Emmeti X-Evo - XX 17X3E R32 Outdoor unit in the language / languages: English as an attachment in your email.

The manual is 4,81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Emmeti X-Evo - XX 17X3E R32 Outdoor unit

Emmeti X-Evo - XX 17X3E R32 Outdoor unit Usermanual and installation guide - German - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info