667124
2
Zoom out
Zoom in
Previous page
1/2
Next page
TA S02M T001 MB 019740A2 050911
1
TA S02M T001 MB 019740B2 050911
2

Suitable for 230 V~ or 24 V~ operation with switching load up to 5
(1) amps.
Red LED light shows when the thermostat is calling for heat.
Adjustable night setback temperature for improved day and night
comfort.
Optional remote sensors - enables thermostat use in bathroom
applications.
Temperature settings from 6 °C to 30 °C.
Wall mounted thermostat in elegant white design, only 85 mm wide x 85 mm high x 31 mm deep.
Accurate temperature control for maximum comfort - differential 0.5 °C.
Compliant with directives EEC 2004/108 & 2006/95 (CE)
6 Tannery Yard - Witney Street - Burford
Oxfordshire - OX18 4DW - UK
Phone: 01993 824900
Fax: 01993 824990
Email: sales@emmeti.co.uk
Website: www.emmeti.co.uk


This electronic room thermostat (Fig. 1) is suitable
for reliable and accurate temperature regulation in
commercial and industrial premises as well as for
home installation.

When the measured room temperature is below the
value set on the internal trimmer the thermostat
turns the relay on and, at the same time, turns the
red LED on for 'Heating'.

Through the internal temperature adjustment
trimmer, see (
) Fig. 6, the user can set the
temperature around which the regulation will take
place, as explained above.


The thermostat should be positioned about 1.5m
from floor level and must avoid being positioned
near draughts, sources of heat or cold or direct
sunlight. To install the thermostat:
Remove the front cover by disengaging the two
plastic teeth on the right hand side of the case
as shown in Figs. 3 & 4.
The thermostat has been designed for fixed
wiring only. Cable access is through the rear of
the mounting backplate as shown in Fig. 2
The backplate can be secured either to a flat
vertical mounting surface or to a single gang flush
mounted wiring box: the fixing centres are shown in
Fig. 2
Fix the thermostat backplate to the wall through
the two screw holes with distance between
centres of 60 mm.
Make the wiring connections to the backplate as
shown in Fig. 5 including any remote sensor
connections to terminals 6 and 7.
When the electrical connections are complete,
refit the cover by aligning the four plastic teeth
on the backplate with the holes in the cover and
then press gently to snap them together.

Terminal Fig. 5 energises the "night setback"
mode. The night setback temperature is adjustable
from 2 °C to 7°C by means of the internal trimmer
(
) Fig. 6. The trimmer is factory set to 4.5°C.

When using the remote sensor option with the
thermostat, connect the sensor as shown in Fig. 5
(
) and remove the jumper on the bottom right hand
corner of the backplate - see (
) Fig. 6. Cased
remote sensors must be connected in cable of at
least 1.5mm
2
cross sectional area and not greater
than 25m in length. Do not put mains cables and
sensor cables next to one another.

Power supply:
U9 132 075: 230V~ -15% +10% 50Hz
U9 132 085: 24V~/= -15% +10% 50Hz
Power absorption: 1VA
Regulation range: 6°C .. 30°C
Night set back: 2°C .. 7°C (Default 4,5°C)
Sensor type: NTC 4,7k
@ 25°C
internal
Remote sensor
optional: U9 132 011
U9 132 012
Contact rating: 5 (1) A @ 250V~ SPDT
Protection grade: IP 30
Operating temperature: 0°C .. 40°C
Storage temperature: -10°C .. +50°C
Humidity limits: 20% .. 80% RH
(non condensing)
Case: Material: ABS self extinguishing V0
Color: Signal white (RAL 9003)
Size: 85 x 85 x 31 mm
(W x H x D)
Weight: U9 132 075: ~135 gr.
U9 132 085: ~ 130 gr.
In view of the constant development of their products,
the manufacturer reserves the right to change technical
data and features without prior notice. The consumer is
guaranteed against any lack of conformity in
accordance with the European Directive 1999/44/EC as
well as the manufacturer’s own warranty policy. The full
text of the warranty is available on request from Emmeti
UK Ltd.
.
Cable Aperture
38 mm
10 mm
43 mm
82 mm
60 mm
41 mm
82 mm


3NL
8
7
654
2
3
7
6
54
2
3
7
6
54



230V~
LN
M
NO NC
LN
C
435
ELECTRONICS
SENSOR
REMOTE
78
NSB
6
NIGHT
SET BACK
~

TIME SWITCH
CONTACTS FOR
OPERATION OF
NIGHT SETBACK
MODE
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Emmeti CS11-U9132075-085 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Emmeti CS11-U9132075-085 in the language / languages: English as an attachment in your email.

The manual is 0,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info