- 10 -
The hot air exhaust hose is not connected
or blocked.
Connect or clean the hot air exhaust
hose.
Temperature setting is too high.
Reset the temperature.
Air inlet is blocked.
Clean the air inlet.
Noisy
The ground is not level or not flat enough.
Place the appliance on a flat, level
surface if possible.
The sound comes from the flowing of the
refrigerant inside the appliance.
It is normal.
E0 Code
Room temperature sensor failed.
Replace the room temperature sensor.
Contact authorized service technician
for repair.
E1 Code
Condenser temperature sensor failed.
Replace condenser temperature sensor.
Contact authorized service technician
for repair.
E2 Code
Water tank full when cooling.
Take off the rubber stopper and empty
the water.
E3 Code
Evaporator temperature sensor failed.
Replace evaporator temperature sensor.
Contact authorized service technician
for repair.
TECHNICAL DATA
Notice: Operation temperature range:
Maximum cooling
Minimum cooling
Dry bulb temperature /
Wet bulb temperature()
35/24
18/12
Below data for your operating reference
Model
PAC-122838
PAC-122839
Rated voltage
220-240V
220-240V
Rated frequency
50Hz
50Hz
Rated input
785W
1000W
Rated current
3.5A
4.5A
Cooling capacity
2050W
(7000Btu/h)
2600W
(9000Btu/h)
Moisture removal (L/H)
0.8
1.0
Air flow
320m³/h
320m³/h
ERP INFORMATION
Value
Value
Trademark
Emerio
Emerio
Model identification
PAC-122838
PAC-122839
Sound power (cooling)
65dB(A)
65dB(A)
Name of refrigerant
R290 (0.14kg)
R290 (0.16kg)
Rated power input for cooling (kW)
0.785
1.0
Rated energy efficiency ratio
2.6
2.6
GWP (kgCO
2
eq)
3
3
Energy efficiency class
A
A
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Emerio PAC-122838 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Emerio PAC-122838 in the language / languages: English, German, Dutch, French, Swedish, Finnish as an attachment in your email.

The manual is 2,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info