4) Using the PLUS(+) or MINUS (-) keys select the desired wind
direction and use the SET key to confirm or cancel each direction
input
5) Press ALARM key to confirm and press the MIN/MAX key to re-
turn the normal display mode or press the ALARM once more to
toggle to another alarm setting mode.
Storm warning alarm setting
Unlike the other weather alarms, the storm warning alarm is set by
entering the main manual setting mode as follows:
10) Press the SET key to enter the manual setting mode
11) Continue to press the SET key until the Storm warning icon
flashes (tendency arrow flashing downwards with the pressure
values flashing)
12) Set the desired hPa pressure value (3 hPa - 9 hPa) using the
PLUS(+) or MINUS(-) keys
13) Press the MIN/MAX key to confirm and return to the normal dis-
play.
Storm warning alarm ON/OFF
After storm warning alarm setting, the next mode to appear after
pressing the SET key is the storm warning ON/OFF. Use the
PLUS(+) or MINUS(-) key to change the status to AON or AOFF.
Default setting is ON:
Should the air pressure drop equal or below the pre-set hPa value
within the last 6 hour period, then the downward tendency arrow will
flash as an indication of possible storm. The base station will take
hourly measurements as a point of reference. The storm-warning
indicator will stop flashing once the air pressure becomes more sta-
ble.
Master Alarm – BUZZER OFF
The time and all the weather alarms may have buzzer sound set to
OFF by holding the MINUS(-) key down for about 3 seconds in normal
display mode and the BUZZER OFF icon appears on the bottom left
of the LCD. When the BUZZER OFF is displayed, the time and all
other weather alarms when activated will only flash but not sound
regardless if that particular alarm has been set to the ON. To deacti-
vate the BUZZER OFF, press the MINUS(-) key once more.
General Alarm Icon
The general alarm icon on the bottom right corner of the LCD will
appear when any weather alarm is activated to show the user that a
set weather condition has been reached. The activated alarm can be
determined by checking the set alarm values against the MIN/MAX
values reached. To deactivate the general weather alarm icon, press
the ALARM key.
Important
When entering the alarm set mode for a specific weather or tempera-
ture condition, the corresponding alarm is automatically enabled (ON)
when the SET key is pressed, regardless of its previous setting and
the alarm value will flash to indicate that it has been activated. Press
the ALARM key to confirm the setting and continue pressing the
ALARM key to toggle through each alarm mode until it returns to the
normal display mode or press the MIN/MAX key at any time to exit the
alarm setting modes.
When a set weather alarm condition has been activated, that particu-
lar alarm will sound and flash for approximately 2 minutes but will
continue to flash until weather conditions have become more steady.
Weather Alarms
The weather alarms are settable for when certain weather conditions
are met according to the users requirements. For example, the user
can set the thresholds for the outdoor temperature to +40°C (high)
and -10°C (low), whilste only enabling the high alarm and disabling
the low alarm (i.e. temperatures <-10°C won’t trigger alarm, but tem-
peratures >+40°C will).
Alarm setting Minimum Maximum
Storm threshold 3 hPa 9 hPa
Air Pressure 920.0 hPa 1080.0 hPa
Outdoor Tempera-
ture
-30.0°C +69.9°C
Indoor Temperature -9.9°C. No alarm will
sound if the minimum
indoor temperature alarm
is set below -9.9ºC.
+59.9°C
Humidity (all) 20% RH 95% RH
Rainfall 24h 0.0 mm 1000 mm.
Rainfall 1h 0.0 mm 1000 mm
Wind 0.0 m/s 50.0 m/s
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ELV WS2300 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ELV WS2300 in the language / languages: English as an attachment in your email.

The manual is 0,47 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info