Through’ will be disabled to allow free access to the
Control Panel to disarm the system before the
entry-delay expires an alarm occurs.
If access is gained via a zone that is not configured as
‘Master Walk Through’, the ‘Slave Walk Through’ zones
will operate as normal according to their programmed
Entry-Delay setting.
Note: A zone set as a ‘Master Walk Through’ zone
must be configured with an Entry-Delay.
OMIT ZONE
A zone may be temporarily omitted when the system is
armed using the Omit feature. When the system is next
disarmed any zones set to Omit will be cancelled.
ZONE LOCKOUT
If a detector on an active zone is triggered while the
system is armed an alarm condition will occur. After
the programmed alarm duration has expired the alarm
will stop and the system will automatically reset.
Subsequent detectors triggered will again initiate an
alarm condition. If a single zone initiates an alarm
condition more than three times then that zone will be
‘Locked Out’ and any further alarm signals from that
zone will be ignored until the system is disarmed.
Note: The ‘Zone Lockout’ feature can be disabled if
required.
EVENT LOG
The Control Panel incorporates a memory capable of
storing the last 50 system events. This enables the
user to see which user has Armed/Disarmed the
system and if and when any alarms occurred. The
time, date and details of the event type will be recorded
for each system event.
CHIME
Chime is a low security facility for use when the system
is Standby mode. If the Chime feature is ON, and a
detector on a zone that has its Chime function enabled
is triggered, the internal sounder will produce a low
volume warning tone. A typical use of the Chime
function would be to warn that a door or particular area
has been accessed.
VOICE DIALER
If the Voice Dialer is enabled and an alarm condition
occurs, the system will call for help using your recorded
alarm messages and up to four telephone numbers.
When an alarm condition occurs, the telephone voice
dialer (if enabled) will call the first enabled number in
the calling sequence and replay the recorded alarm
messages for the configured ‘Play Time’. The recipient
must acknowledge the message by pressing the
button on their telephone keypad. If the call is
unanswered or an acknowledgment is not received
then the next active number in the dialing sequence will
be called. The dialer will continue calling each
number in turn until either all numbers in the sequence
have been dialed the set number of times or the
sequence is cancelled/acknowledged by the recipient.
DIGITAL DIALER
As an alternative to the Voice dialer the system may be
configured to interface with a central monitoring station.
LATCH KEY
When the system is disarmed the Latch-Key facility, if
enabled, will call the first latchkey phone number and
replay the user message (recorded under user setup)
for the set ‘Play Time’. The recipient must
acknowledge the message by pressing the
button on the telephone keypad. If the call is
unanswered or an acknowledgment is not received
then the second latchkey phone number will be called.
The voice dialer will continue calling each number in
turn until each number has been dialed the set number
of times or the sequence is cancelled/acknowledged by
the recipient.
For example, the latchkey facility is useful to inform
parents that a child has returned from school and
disarmed the system.
ANSWER PHONE
The Control Panel includes an answer-phone facility.
The answer phone will record and store a maximum of
6 messages with each message being limited to a 30s
duration.
Messages may be retrieved either direct from the
Control Panel or by dialing into the system from a
phone.
VOICE MEMO
In addition it is also possible to record messages at the
Control Panel using the ‘Voice-Memo’ facility. Each
voice-memo message is limited to a maximum duration
of 30s and counts as an answer phone message.
REMOTE SYSTEM CONTROL
It is possible to dial into the system via the connected
telephone line to interrogate the system status and to
have basic control over the system, (e.g. to Arm and
Disarm the system). You may also activate the
microphone on the control panel to Listen-In to what is
3
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elro AP5500 - Pro Alarm System at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elro AP5500 - Pro Alarm System in the language / languages: English as an attachment in your email.

The manual is 3,52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Elro AP5500 - Pro Alarm System

Elro AP5500 - Pro Alarm System Quick start guide - English - 8 pages

Elro AP5500 - Pro Alarm System Quick start guide - German - 10 pages

Elro AP5500 - Pro Alarm System Quick start guide - Dutch - 8 pages

Elro AP5500 - Pro Alarm System User Manual - Dutch - 42 pages

Elro AP5500 - Pro Alarm System Quick start guide - French - 9 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info