14. Troubleshooting
13-1 Basic Troubleshooting
13-1-1 The alarm panel cannot register with a GSM host (GSM Net LED flashes
rapidly):
a. SIM card not inserted or bad contact.
b. SIM card needs to be unlocked before use (use a mobile phone to setup) to
cancel the input of PIN code or PUK code.
c. Change the position of the AG400011.
d. Remove AC power and batteries and insert the SIM card again.
e. Make sure the SIM card is not expired.
13-1-2 Mobile phone cannot configure the alarm nor receive SMS from it:
a. The Show Caller ID function on this mobile phone must be turned on. The alarm
panel will not accept any commands if it cannot recognize the sender’s Caller ID.
b. Only a phone number set as Host phone number may have administrator rights to
configure parameters such as Voice, SMS, Speed Dial numbers, delay time,
Siren, volume, and starting time. Normal SMS numbers will not be accepted.
c. If GSM is busy or has bad signal, the SMS may be delayed or not sent.
d. When operating SMS from a mobile phone, please wait for the alarm panel to
return the SMS before operating the next SMS. Resend the SMS if one minute
has passed and the alarm panel still did not sent the return SMS.
e. When operating SMS from a mobile phone, if there are no responses the reason
might be the sent SMS is not an acceptable command. Please refer to SMS
Functions in Appendix B for the proper commands.
13-1-4 GSM Status LED is off:
a. Check the AC adaptor to see if it’s properly plugged in and check the power LED
to see it it’s on. The GSM will shut down partial power when it is not connected to
AC power to extend usage time.
b. Remove all power sources (including batteries and AC power), insert them back
and try again
13-1-5 Unable to use RFID Tag after power on
Remove all power sources including batteries and DC-jack. Wait for one minute
and power on the alarm panel again.
13-2 Restore to factory settings
The user may choose to perform a factory reset to return the device to factory default
settings. Please note that all configurations (including recorded alarm messages,
contact lists and linked sensors/devices) will be deleted. The PIN code will reset back
to default PIN code “1234”.
1. Take the device off the wall. Note the alarm will sound because of its tamper
protection.
2. Remove all power sources including batteries and DC-jack.
3. Press and hold the reset button on the back (next to DC-jack) and insert the
batteries or DC-jack to power it on. Keep pressing the reset button until a beep
tone is heard. Release the button after beep tone.
4. The DISARM LED will turn on to followed by 5 short beeps indicating the reset to
factory default is complete.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elro AG400011 - Home Alarm System at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elro AG400011 - Home Alarm System in the language / languages: English as an attachment in your email.

The manual is 0,43 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Elro AG400011 - Home Alarm System

Elro AG400011 - Home Alarm System Quick start guide - English - 6 pages

Elro AG400011 - Home Alarm System Quick start guide - German - 5 pages

Elro AG400011 - Home Alarm System User Manual - German - 12 pages

Elro AG400011 - Home Alarm System Quick start guide - Dutch - 5 pages

Elro AG400011 - Home Alarm System User Manual - Dutch - 236 pages

Elro AG400011 - Home Alarm System Quick start guide - French - 9 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info