signal strength indicated as:
- LED 1 :Good, LED 2: Normal, LED 3: Poor,
- ALARM LED : No Signal / SIM card registration failure / No SIM card
Siren enable/disable
6. Press 8 for 3 or more seconds during Test Mode would send a System On / Off
command to the Wireless Siren.
SMS test
7. Press 9 for 3 or more seconds during Test Mode would send a test SMS message
(including the current Alarm Mode, Delay Time, Siren On/Off, and Alarm Time) to
the Host Phone number.
7-6 Changing the PIN code
For security reasons it is strongly advised to change the default PIN code to a 4-digit
number of your choice. This prevents unauthorized access of your alarm panel from
its keypad.
Enter Old PIN + 06 + PARM + New PIN + PARM. The new PIN code will take effect
immediately.
8. Arming /Disarming the Alarm panel
8-1 Fully Arm Mode
1. Enter PIN + Arm Key. A long beep will sound if the PIN code is correct. Three
beeps will sound if the PIN code is incorrect.
2. If the PIN code is correct, the system will enter the Exit Delay countdown. The
ARM LED will flash and beep tone will sound once every second.
3. When the countdown reaches 5 second, the beep tone will sound twice every
second.
4. After the countdown is complete the system will enter Arm Mode. The Arm LED
will turn on.
8-2 Disarm Mode
1. Enter the PIN + DISARM Key. A long beep will sound if the PIN code is correct.
Three beeps will sound if the PIN code is incorrect.
2. If the PIN code is correct, the system will enter Disarm Mode immediately.
Note:
a. Remote keyfobs, Wireless Keypad, and SMS/App can be used to operate Arm /
Partial Arm / Disarm the system.
b. RFID Tags can be used to Disarm only. Simply swipe the tag in the area above
the siren on the alarm panel. An SMS will be sent to the Host Phone Number if
disarmed by RFID Tag. The SMS content can be modified for Tags 1-4 (e.g. “Jack
came home”, “Daniel disarmed”). SMS content for Tags 5-50 cannot be modified.
c. Contacts listed in Alarm SMS Phone number list can Arm, Partial Arm and
Disarm by SMS or App
8-3 Partial Arm Mode
1. Enter the PIN + PARM Key. A long beep will sound if the PIN code is correct.
Three beeps will sound if the PIN code is incorrect.
2. If the PIN code is correct, the system will enter the Exit Delay countdown. The
PARM LED will flash and beep tone will sound once every second.
3. When the countdown reaches 5 second, the beep tone will sound twice every
second.
4. After the countdown is complete the system will enter Partial Arm Mode. The
PARM LED will turn on.
.
8-4 One Key Alarm Mode
The alarm panel provides an easy one key step to set Arm and Partial Arm mode:
From Disarm Mode:
- Press and hold ARM Key for 3 or more seconds to enter Fully Arm Mode;
- Press and hold PARM Key for 3 or more seconds to enter Partial Arm Mode.
8-5 Open Door / Window Alert:
This feature checks if the door or window is left open when trying to Arm or Partial
Arm the system.
1. To turn on this feature, enter PIN + 08 + 1 + PARM
2. If a door/window sensor reports an open condition then the alarm panel will beep
for 10 seconds, and the keypad LED will indicate which sensor zone number 1 – 9
(0 for other Sensor Zones).
3. After the alert has ended it will enter the configured alarm mode. If all
doors/windows are closed the alert sounds will turn off.
You may also do a quick check while in Disarm mode:
- Pressing the ARM Key will check all doors and windows under Fully Arm and
display sensor number LED of opened doors or windows for 3 seconds.
- Pressing the PARM Key will check all doors and windows under Partial Arm and
display LED opened doors or windows for 3 seconds.