Side 7
DIODE TEST
Default er . Tryk SELECT knappen kortvarigt to gange for at vælge diode
test funktion. Normal forward spændingsfald (forward biased) for en god silicon
diode er i mellem 0.400V til 0.900V. Et højere resultat indikerer en defekt diode.
En nulaflæsning indikerer en kortsluttet diode (defekt). En OL aflæsning indikerer,
at dioden er åben (defekt). Byt om prøveledningerne (reverse biased) kryds
af dioden. Displayet viser OL, hvis dioden er god. Hvilket som helst andet viser, at
dioden er defekt.
KAPACITETSFUNKTION
Default at . Tryk SELECT knappen kortvarigt tre gange for at vælge
Kapacitet funktionen. Relativ nul kan ved måling af meget små kapaciteter
bruges til nulstilling af prøveledninger og den interne beskyttelseskreds der er i
instrumentet.
ADVARSEL
Aflad kondensatorerne før der måles dem . Store værdier bør aflades ved
hjælp af en dertil indrettet modstandskreds.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elma 805s at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elma 805s in the language / languages: English, German, Danish, Swedish, Norwegian as an attachment in your email.

The manual is 4,12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info