668440
50
Zoom out
Zoom in
Previous page
1/52
Next page
Elma 5800 side 50
500V(0
%~+10
%)
0.500~4.000
M
0.001M
+(2%+10)
1mA
@lo
ad50
0k
1mA
4.001~40.00
M
0.01M
+(2%+10)
40.01~400.0
M
0.1M
+(2%+5)
400.1~4000 M
1M
+(4%+5)
1000V
(0%~+1
0%)
1.000~4.000
M
0.001M
+(3%+10)
1mA
@lo
ad1
M
1mA
4.001~40.00
M
0.01M
+(2%+10)
40.01~400.0
M
0.1M
+(2%+5)
400.1~4000 M
1M
+(4%+5)
Note: Accuracy specifications consist of two elements:
(% reading) – This is the accuracy of the measurement circuit.
(+ digits) – This is the accuracy of the analog to digital converter.
Store capacitance 2000
Enclosure: Double molded, waterproof
Shock (Drop Test): 6.5 feet (2 meters)
Diode Test: Test current of 0.9mA maximum, open circuit voltage 2.8V DC
typical
Continuity Check: Audible signal will sound if the resistance is less than 35
(approx.), test current <0.35mA
PEAK: Captures peaks >1ms
Temperature Sensor: Requires type K thermocouple
Input Impedance: >10M VDC & >9M VAC
AC Response: True rms
AC True RMS: The term stands for “Root-Mean-Square,”
which represents the method of calculation
of the voltage or current value. Average responding multimeters
are calibrated to read correctly only on sine waves and they
will read inaccurately on non-sine wave or distorted signals. True
rms meters read accurately on either type of signal.
ACV Bandwidth: 50Hz to 1000Hz
Crest Factor: 3 at full scale up to 500V, decreasing linearly to 1.5 at 1000V
Display: 40,000 count backlit liquid crystal with bargraph
Overrange indication:OL” is displayed
Auto Power Off: 15 minutes (approximately) with disable feature
Polarity: Automatic (no indication for positive); Minus (-) sign for negative
Measurement Rate: 2 times per second, nominal
Low Battery Indication: “ ” is displayed if battery voltage drops below operatingvoltage
Battery: One 9 volt (NEDA 1604) battery
Fuses: mA, µA ranges; 0.5A/1000V ceramic fast blow A range;
10A/1000V ceramic fast blow
Operating Temperature:41ºF to 104ºF (5ºC to 40ºC)
Storage Temperature: -4
o
F to 140
o
F (-20
o
C to 60
o
C)
50


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elma 5800 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elma 5800 in the language / languages: English, Danish, Swedish, Norwegian as an attachment in your email.

The manual is 2,02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info