Example Applications (continued)
82 of 94ELM327DSJ Elm Electronics – Circuits for the Hobbyist
www.elmelectronics.com
ELM327
the rest.
We do caution that the MAX3222E does seem to
place some extra demands on the 5V power supply. It
should work fairly well with the 7805 regulator that we
show in Figure 9, but if you have chosen a lower
current device like the 78L05 or LP2950, you may
experience occasional ‘LV RESET’s. If you do, we
recommend adding two capacitors to the circuit of
Figure 9. We suggest that a 10 µF 50V capacitor be
connected in parallel with C1, and also that a 33 µF
10V unit be installed across C5 (the 5V ‘rail’). This
should eliminate problems, but if it does not, you may
also wish to consider a more powerful regulator (such
as the 7805 that we show in Figure 9) if you do not
already have one installed.
The USB interface of Figure 13 provides another
way to connect the ELM327 to USB systems. It uses a
Silicon Laboratories (www.silabs.com) CP2102 chip to
convert between the ELM327’s serial data and USB.
One of the advantages of going to a USB interface
is the high serial baud rates that you may experience.
In order to use these higher rates, you will have to
program both the USB interface and the ELM327
interface for them.
The CP2102 interface baud rate is actually
configured by driver software. When you set the baud
rate in your terminal program, the software does what
is necessary to configure the CP2102 for operation at
that rate and you do not need to do anything more.
The ELM327 initially only uses a 38,400 bps rate,
however, and must be told to use anything different.
In order to change from the standard 38.4 k baud
rate, you must first set your software to 38.4 kbps, and
power up your ELM327 circuit. Make sure that it is
working, as described in the ‘Communicating with the
ELM327’ section, before you do anything else. When
you are confident that all is well, you can then change
the baud rate. Before doing so, we caution that you
should check to be sure that your software actually
supports the desired rate (as several can not handle
more than about 250 kbps).
The CP2102 chip is able to support a 115.2 kbps
rate natively, and almost all software should be able to
support it as well, so we will use that rate to provide an
example.
First, while connected to the ELM327 at 38.4 kbps,
we need to change the default rate to 115.2 kbps. No
need to worry that this will affect your communications,
as it will not take effect until the ELM327 has been
reset. To change the data rate, simply change the
Figure 12. An High Speed
RS232 Interface ( 250 kbps)
2 (RxD)
3 (TxD)
5 (SG)
1 (DCD)
4 (DTR)
6 (DSR)
7 (RTS)
8 (CTS)
0.1µF
1
2
3
4
5
6
7
8
9
RS232
Interface
(DB9F)
+5V
0.1µF
+5V
327
0.47µF
0.47µF
0.47µF
+5V
327
2 (D-)
USB
Interface
(type ‘B’
connector)
+5V
1 (+5)
4 (SG)
3 (D+)
SiLabs
CP2102
0.1µF
5.0V
TVS
1µF
7
6
26 25
3
4
5
8
Figure 13. An Alternative USB Interface
82


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elm 327 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elm 327 in the language / languages: English as an attachment in your email.

The manual is 0,23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info