741486
10
Zoom out
Zoom in
Previous page
1/120
Next page
www.absolualarme.com met à la disposition du public, via www.docalarme.com, de la documentation technique dont les références, marques et logos, sont la propriété des détenteurs respectifs
(((ELKRON))) - MP110
2.3 Description du Bornier
1/2 LA/LB Entrée ligne téléphonique
3/4 PA/PB Sortie ligne téléphonique
5 Borne de terre
6 - Négatif d'alim. de la carte
7 + Positif d'alim. de la carte
8 C Test batterie
9 -BAT Négatif batterie
10 +BAT Positif batterie
11 -SIR Négatif d'alimentation sirène
12 +SIR Positif d'alimentation sirène
13 C
14 NO Sortie 1 à relais, débit max1 A 24Vdc
15 NC
16 U2 Sortie 2 électrique Open Collector (I max 10mA)
17 U3 Sortie 3 électrique Open Collector (I max 10mA)
18 U4 Sortie 4 électrique Open Collector (I max 10mA)
19 U5 Sortie 5 électrique Open Collector (I max 10mA)
20 -SER Alimentation BUS
21 +SER Alimentation BUS
22 CK Ligne série horloge
23 D Ligne série données
24 -S Négatif alimentation détecteurs
25 +S Positif alimentation détecteurs
26 Z1 Zone 1: entrée programmable
27 Z2 Zone 2: entrée programmable
28 Z3 Zone 3: entrée programmable
29 Z4 Zone 4: entrée programmable
30 Z5 Zone 5: entrée programmable
31 Z6 Zone 6: entrée programmable
32 Z7 Zone 7: entrée programmable
33 Z8 Zone 8: entrée programmable
34 -S Négatif alimentation détecteurs
35 +S Positif alimentation détecteurs
36 TA Entrée 24h
37 KEY Entrée clé mecanique
PS108
Il est possible de programmer, à l’aide
des cavaliers, le type de sortie
électrique (NPN/PNP) de U2, U3, U4,
U5. En laissant les cavaliers tels qu’ils
sortent d’usine (voir dessin ci-
dessus), la sortie électrique est
normalement élevée (+12V) au repos
(PNP) qui manquera en cas d’alarme.
Inversement la sortie devient de type
NPN, c’est à dire normalement basse
(0V) au repos, qui rejoint le niveau
élevé (+12V) en cas d’alarme.
PROGRAMMATION NIVEAU
SORTIES
U2
U3 U4 U5
10
F3-F1A-250V
F1-F1A-250V
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elkron MP110M at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elkron MP110M in the language / languages: French as an attachment in your email.

The manual is 1,58 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Elkron MP110M

Elkron MP110M User Manual - English - 20 pages

Elkron MP110M User Manual - German - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info