741484
19
Zoom out
Zoom in
Previous page
1/20
Next page
(((ELKRON)))
MP110 USER MANUAL
(((ELKRON)))
MP110 USER MANUAL
2.Access Codes
The unit can be programmed so as to enable User 2 (e.g., service
personnel, custodian, porter , telemonitoring, private vigilance, etc)
to have his own secret access code which allows him to arm/disarm
the unit without performing other operations.
The unit identifies up to a maximum of 8 different assigned codes and
as many users:
After entering a correct code that is enabled, the unit’s buzzer beeps
twice, or it beeps once at length to indicate an error. The Master user’s
code is always enabled; the other codes must instead be enabled (refer
to par. “Code Enabling”).
If the engineer’s code is enabled, it remains enabled until the Master
user’s code is again entered to partially or totally arm the system, or
until the first arming by electronic key-
Once armed, every re-entry/EXCLUDED display procedure triggers a
1-minute delay (that is reset each time the key is pressed). If a delay
time-out occurs, the procedure is exited automatically without saving
the changes made.
• Each time the key is pressed on the KP100 keypad (segmented
display), while entering the secret code, a segment of the display lights
up to display the digits (entered) as they are typed in.
FACTORY
CODE
CODE 1 - MASTER USER 1 11111
CODE 2 - USER 2 2 22222
CODE 3 - ENGINEER 3 33333
CODE 4 - TELEMONITORING 4 44444
CODE 5 - USER 5 5 55555
CODE 6 - USER 6 6 66666
CODE 7 - USER 7 7 77777
CODE 8 - USER 8 8 88888
Each user is assigned and “identification
number “ (from 1 to 8) that is to be typed
in before the code; this number allows
the unit to identify the user of the system.
To be identified by the system, the owner
must type in the number 1 followed by
his personal code; any other users will
instead type in the number 2, 3, 4, 5, 6,
7 or 8, followed by his personal code
19
3. System Arming/Disarming
For ARMING of the system, enter a valid code associated to the 3
sectors and press the
TOTAL
key.
Leds
1
3
,
2
and
3
flash, and after 4 seconds they
light up with a fixed light.
If there is an an exit delay, it is indicated by the intermittent sound of the
buzzer.
To DISARM the system, enter a valid code and press the
TOTAL
key.
Leds
1
3
,
2
and
3
corresponding to active sectors
go OFF and thebuzzer beeps twice.
To partially ARM the system, enter a valid code and press the key for
the zone or zones ne wishes to arm.
1
to arm Zone 1 - the Led
1
3
flashes and lights up with a fixed
light after 4 seconds
2
to arm Zone 2 - the Led
2
flashes and lights up with a
fixed light after 4 seconds
3
to arm Zone 3 - the Led
3
flashes and lights up with a fixed
light after 4 seconds
To DISARM the system, enter a valid code and press the
TOTAL
key. The
leds in the previously armed zones go OFF and the buzzer beeps twice.
During partial arming, about 5 seconds are available (led flashes) within
which it is possible to correct the type of arming; once this time is up,
the leds light up with a fixed light and the sectors are armed.
• After selecting the desired configuration for the zones, arming is
confirmed by pressing the
A
key without waiting for the time
available for arming to expire.
3.1 Away Arming/Disarming
3.2 Partial Arming/Disarming
22
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elkron MP110 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elkron MP110 in the language / languages: English as an attachment in your email.

The manual is 0,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Elkron MP110

Elkron MP110 User Manual - German - 32 pages

Elkron MP110 User Manual - French - 120 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info