PAR. BESCHREIBUNG BEREICH APP1 APP2 APP3 APP4 M.E.
SEt Sollwert der Temperaturregelung LSE ... HSE 0,0 0,0 0,0 0,0 °C/°F
VERDICHTER (Registerkarte “CP”)
diF diFferential. Schaltdifferenz des Verdichterrelais 0,1 ... 30,0
2,0 2,0 2,0 2,0
°C/°F
HSE Higher SEt. Einstellbarer Höchstwertr Sollwert LSE ... 302 99,0 99,0 99,0 99,0 °C/°F
LSE Lower SEt. Einstellbarer Mindestwert für Sollwert -58,0 ... HSE -50,0 -50,0 -50,0 -50,0 °C/°F
OSP
Temperaturwert, der bei Freigabe des reduzierten Sollwerts (Economy-Funktion) zum
Sollwert addiert werden muss
-30,0 ... 30,0 3,0 3,0 0,0 3,0 °C/°F
Hc Regelungsmodus. “H“ = Heizen, ”C“ = Kühlen C/H C C C C Flag
Ont
Einschaltzeit des Reglers bei Fühlerdefekt.
bei Ont=1 und OFt=0 bleibt der Verdichter permanent eingeschaltet;
bei Ont=1 und OFt>0 arbeitet er in der Betriebsart Duty Cycle
0 ... 250 0 0 0 0 min
OFt
Abschaltzeit des Reglers bei Fühlerdefekt.
bei OFt=1 und Ont=0 bleibt der Regler permanent ausgeschaltet;
bei OFt=1 und Ont>0 arbeitet er in der Betriebsart Duty Cycle
0 ... 250 1 1 1 1 min
dOn Vergerungszeit für Aktivierung des Verdichterrelais nach Anforderung 0 ... 250 0 0 0 0 Sek.
dOF Verzögerungszeit nach Abschaltung und anschliender Einschaltung 0 ... 250 0 0 0 0 min
dbi Verzögerungszeit zwischen zwei aufeinander folgenden Einschalten des Verdichters 0 ... 250 0 0 0 0 min
OdO
(!)
Verzögerungszeit für die Aktivierung der Ausnge nach Einschalten des Geräts oder
nach einem Stromausfall. 0 = nicht aktiv
0 ... 250 0 0 0 0 min
dCS Sollwert “Schockkühlzyklus” -58,0 ... 302 0,0 0,0 0,0 0,0 °C/°F
tdc Dauer “Schockhlzyklus” 0 ... 255 0 0 0 0 min*10
dcc Verzögerung Abtauaktivierung nach “Schockhlzylus 0 ... 255 0 0 0 0 min
ABTAUUNG (Registerkarte “dEF”)
dtY
Abtauart.
0 = elektrisches Abtauen;
1 = Abtauen mit Zyklusumkehr;
2 = Abtauung unabhängig vom Verdichter
0/1/2 0 0 0 0 Num
dit Intervallzeit zwischen dem Beginn von zwei aufeinander folgenden Abtauzyklen 0 ... 250 6 6 6 6 Stunden
PARAMETERTABELLE MENÜ “INSTALLATEUR” (IDPLUS 971)
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eliwell IDPlus 961 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eliwell IDPlus 961 in the language / languages: German as an attachment in your email.

The manual is 2,06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info