Electrical & Installation requirements
Electrical requirements
IMPORTANT
Observe all governing codes and ordinances.
It is the customer’s responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation is
adequate and in conformance with National
Electrical Code, ANSI/NFPA 70 — latest
edition*, or CSA Standards C22.1-94,
Canadian Electrical Code, Part 1 and C22.2
No.0-M91 - latest edition** and all local
codes and ordinances.
If codes permit and a separate ground wire is
used, it is recommended that a qualified
electrician determine that the ground path is
adequate.
Do not ground to a gas pipe.
Check with a qualified electrician if you are
not sure range hood is properly grounded.
Do not have a fuse in the neutral or ground
circuit.
IMPORTANT
Save Installation Instructions for electrical
inspector’s use.
The range hood must be connected with
copper wire only.
The range hood should be connected directly
to the fused disconnect (Or circuit breaker)
box through metal electrical conduit.
Wire sizes must conform to the requirements
of the National Electrical Code ANSI/NFPA
70 — latest edition*, or CSA Standards
C22.1-94, Canadian Electrical Code Part 1
and C22.2 No. 0-M91 - latest edition** and all
local codes and ordinances.
A U.L.- or C.S.A.-listed conduit connector
must be provided at each end of the power
supply conduit (at the range hood and at the
junction box).
Copies of the standards listed may be obtained
from:
* National Fire Protection Association
Batterymarch Park Quincy, Massachusetts 02269
** CSA International 8501 East Pleasant Valley
Road Cleveland, Ohio 44131-5575
Before installing the hood
1. For the most efficient air flow exhaust,
use a straight run or as few elbows as
possible.
CAUTION: Vent unit to outside of
building, only.
2. At least two people are necessary for
installation. Wear gloves to protect
against sharp edges.
3. Fittings material is provided to secure the
hood to most types of walls/ceilings,
consult a Qualified Installer, check if they
perfectly fit with your cabinet/wall.
4. Do not use flex ducting.
5. COLD WEATHER installations should
have an additional backdraft damper
installed to minimize backward cold air
flow and a nonmetallic thermal break to
minimize conduction of outside
temperatures as part of the ductwork.
The damper should be on the cold air
side of the thermal break.
The break should be as close as possible
to where the ducting enters the heated
portion of the house.
6. Make up air: Local building codes may
require the use of Make-Up Air Systems
when using Ducted Ventilation Systems
greater than specified CFM of air
movement.
The specified CFM varies from locale to
locale. Consult your HVAC professional
for specific requirements in your area.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elica Juliette at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elica Juliette in the language / languages: English, French, Spanish as an attachment in your email.

The manual is 0,83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Elica Juliette

Elica Juliette Usermanual and installation guide - English - 11 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info