the weight of the hood. Do not tile, grout or silicone this
appliance to the wall. Surface mounting only.
In the case of the presence of panels and/or walls and/or
lateral wall units check that there is sufficient space to install
the hood and that access to the command panel is easy.
An aesthetic flue can be purchased as an optional accessory.
Check with the assistance centre whether the model in your
possession envisages this possibility.
We advise installing the hood after having purchased the flue
to check with certainty the most suitable installation.
Operation
Use the high suction speed in cases of concentrated kitchen
vapours. It is recommended that the cooker hood suction is
switched on for 5 minutes prior to cooking and to leave in
operation during cooking and for another 15 minutes
approximately after terminating cooking.
Model with touch panel
To select the functions of the hood just touch the commands.
1. Button ON/OFF motor
Press this button to turn on the hood; the suction speed
(power) 1 is selected.
With the hood on (at any speed), press this button to turn
the hood off.
2. Button for suction speed (power) decrease
3. Button for suction speed (power) increase – the
selected speed can be distinguished from the colour of
the panel:
Suction speed (power) 1: bright white
Suction speed (power) 2: light blue
Suction speed (power) 3: dark blue
Intensive suction speed (power): flashing dark blue
Note: Intensive suction speed (power) is active for a
limited time (approximately 5 minutes) after which the
hood is automatically positioned at suction speed (power)
2.
4. Button ON/OFF lighting/lights
Saturation indicator
The hood is equipped with a system that can notify via a
dedicated indicator, when it is necessary to perform
maintenance of the filters.
The grease filter saturation indicator is always active.
Check the saturation status of the charcoal filter:
Turn off the hood.
Press and hold button 2 for 2 seconds.
Important! Do not hold the button longer, this may change the
saturation indicator related settings (see next paragraph
"Activation of the saturation indicator of the charcoal
filter").
Flashing lighting of the panel: the saturation indicator of the
charcoal filter is disabled, the hood is ready to operate in
ventilation version.
To use the hood in filtering version, the saturation indicator of
the charcoal filter should be activated.
Steady lighting of the panel: the saturation indicator of the
charcoal filter is activated, the hood is ready to operate in
filtering version.
To use the hood in ventilation version, the saturation indicator
of the charcoal filter should be disabled.
Activation of the saturation indicator of the charcoal filter:
Turn off the hood.
Press and hold button 2 for longer than 5 seconds.
Panel lighting will change from "flashing" to "steady" to
indicate that activation was successful.
Disabling of the saturation indicator of the charcoal filter:
Turn off the hood.
Press and hold button 2 for longer than 5 seconds.
Panel lighting will change from "steady" to "flashing" to
indicate that activation was successful.
Filter saturation indicator
The panel lights up at regular intervals:
in steady red, to indicate that it is necessary to perform
maintenance of the grease filter
in flashing red, to indicate that it is necessary to perform
maintenance of the charcoal filter.
To reset the saturation indicator:
Turn off the hood.
Press and hold button 1 for approximately 5 seconds.
Perform filter maintenance.
Temperature Alarm
The hood is equipped with a temperature sensor that activates
the motor in the event that the temperature in the control area
is too high.
This state persists until the temperature falls below the alarm
threshold.
Temperature Alarm
The hood is equipped with a temperature sensor which
activates the motor in case the temperature in the control
panel zone is too high.
This condition remains as such until the temperature falls
below the alarm threshold.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elica Amelie at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elica Amelie in the language / languages: All languages as an attachment in your email.

The manual is 6,53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info