471185
8
Zoom out
Zoom in
Previous page
1/12
Next page
Use
The hood is designed to be used either for exhausting or filter
version.
Ducting version
In this case the fumes are conveyed outside by means of a
special pipe connected with the connection ring located on top
of the hood.
Attention! The exhausting pipe is not supplied and must be
purchased apart.
Diameter of the exhausting pipe must be equal to that of the
connection ring = 150mm.
In the horizontal runs the exhausting pipe must be slightly
slanted (about 10°) and directed upwards to vent the air easily
from the room to the outside.
Attention! If the hood is supplied with active charcoal filter,
then it must be removed.
Filter version
One active charcoal filter is needed for this and can be
obtained from your usual retailer.
The filter removes the grease and smells from the extracted
air before sending it back into the room through the upper
outlet grid.
Note: The recycled air in the charcoal filter is sent back to the
kitchen through a duct which conveys air on a side of the
cabinet (Fig. 11).
Non-return valve locking
Attention, before connecting the flexible air outlet pipe make
sure that the non-return valves of the suction unit can freely
rotate (Fig. 12).
The models with no suction motor only operate in ducting
mode, and must be connected to an external suction device
(not supplied).
The connecting instructions are supplied with the peripheral
suction unit.
Installation
When installing the product, it is recommended to keep a
minimum distance of 400mm between the worktop and any
components laid on top of the hood.
This is to let the suction panel move upwards (opening) and
downwards (closing) without any obstacles, and to facilitate
access to the hood controls on the panel.
WARNING: Put the metal box containing the electronic
components at a distance not shorter than 65 cm from the gas
hob or 65 cm from the hood suction point.
RECOMMENDATION: We recommend you to install the
metal box containing the electronic components at a distance
of at least 10 cm from the ground and sufficiently from all the
sources of heat (e.g.: side of an oven or hob).
If the instructions for installation for the gas hob specify a
greater distance, this must be adhered to.
Electrical connection
The hood must be connected to the mains supply by qualified
and trained technicians.
The mains power supply must correspond to the rating
indicated on the plate situated inside the hood. If provided with
a plug connect the hood to a socket in compliance with current
regulations and positioned in an accessible area. If it not fitted
with a plug (direct mains connection) or if the plug is not
located in an accessible area apply a double pole switch in
accordance with standards which assures the complete
disconnection of the mains under conditions relating to over-
current category III, in accordance with installation
instructions.
Warning! Before re-connecting the hood circuit to the mains
supply and checking the efficient function, always check that
the mains cable is correctly assembled.
Warning! Power cable replacement must be undertaken by
the authorised service assistance centre or similar qualified
person.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elica Adagio at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elica Adagio in the language / languages: English as an attachment in your email.

The manual is 3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Elica Adagio

Elica Adagio User Manual - German, Dutch, Danish, French, Italian, Portuguese, Spanish - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info