820566
13
Zoom out
Zoom in
Previous page
1/56
Next page
USER MANUAL / MANUEL D'UTILISATEUR
BENUTZERHANDBUCH / GEBRUIKSHANDLEIDING (2019)
ELECTRIC SHOCK HAZARD
Read these instructions carefully. Failure to follow them could result in property damage, personal injury, or loss of life.
This control must be electrically wired and operated in accordance with all codes and local regulations. Service and installation
must be performed by a trained, experienced service technician.
Do NOT use the control if you suspect it may be damaged.
IMPORTANT SAFETY INFORMATION
WHAT TO DO IF YOU SMELL GAS
Do NOT operate any appliance.
Do NOT touch any electrical switch; do NOT use any phone in your building.
Immediately evacuate the area and contact the gas supplier. Follow the gas supplier’s instructions.
If you cannot reach the gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency, or the gas supplier. Installation shall conform
with local codes, or in the absence of local codes, in accordance with the National Fuel Gas Code ANSI Z223.1 / NFPA 54 or the
IFGC or CSA B149.1. All piping and tubing must comply with local codes and ordinances.
Use only your hand to push in or turn the gas control knobs. Never use tools. If a knob will not push in or turn by hand, do not try
to repair it. Call a qualified service technician. Force or attempted repair can result in a fire or explosion.
Do NOT use a product if you suspect it has been subjected to high temperatures, damaged, tampered with, or taken apart.
Do NOT use a product if you suspect it has been under water or that liquid has seeped into the product. Any of these incidents
can cause leakage or other damage that may affect proper operation and cause potentially dangerous combustion problems.
Damper position must be in accordance with Manufacturer’s Installation Instructions and all applicable standards. Failure to follow
them could result in a fire or explosion causing property damage, personal injury, or loss of life.
Do NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this control or other appliances.
Read these instructions carefully and completely before installing or operating. Failure to follow them could result in a fire or
explosion causing property damage, personal injury, or loss of life. Service and installation must be performed by a trained /
experienced service technician.
MODES OF OPERATION
When Pilot ignition is confirmed, motor turns automatically
to maximum flame height.
TURN FIRE ON AND OFF
Press and hold the button until two
short beeps confirms the start se-
quence has begun; release button.
Main gas flows once Pilot ignition is
confirmed.
Handset automatically goes into
Manual Mode after main burner
ignition.
Press the
button to turn off
.
If the Pilot does not stay lit after several tries, turn the
main valve knob to OFF and follow the instructions “TURN
OFF GAS TO APPLIANCE” (see page 9).
FLAME HEIGHT ADJUSTMENT
To increase flame height press and
hold + button.
To decrease flame height or to set ap-
pliance to Pilot flame, press and hold
button.
If the appliance will not operate, follow the instructions
“TURN OFF GAS TO APPLIANCE”
1. Insert batteries or connect AC mains power. The module
for circulating fan and light / dimmer includes a mains
adapter. With mains adapter, batteries can be used for
backup.
2. Place ON / OFF switch (if equipped) to ON position.
3. The Receiver has to learn the Handset code:
Press and hold the Receiver’s reset button (see figure 19,
page 11) until you hear two (2) beeps. After the second, longer
beep, release the reset button. Within the subsequent 20 sec-
onds press the button on the Handset. Two (2) short beeps
confirm the code is set. is displayed on the Handset con-
firming the synchronization is in process (see figure 13). After
successful synchronization the current state of the gas fire is
displayed on the Handset.
Figure 3: Synchronization in process
NOTE: This is a one time setting only, and it is not required af-
ter changing the batteries in the Handset or Receiver.
NOTE: Both the Receiver and the Handset transmit and re-
ceive signals (bidirectional). Handset and Receiver
sync status information every 10 s during
rst 2 min
afterward every 4 to 6
min up to 1 h. Touching a Hand-
set button causes an immediate synchronization.
NOTE: When the RF Receiver is placed in the appliance, the
surrounding metal can reduce reception considerably.
SYNCHRONISATION HANDSET/RECEIVER
NOTE: Flame goes to high re rst be-
fore going to low re.
To go to hi re, double-click + button.
DESIGNATED LOW FIRE AND HIGH FIRE
To go to low re, double-click button.
13/56
USER MANUAL
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Element4 SUMMUM 190 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Element4 SUMMUM 190 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 11.39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Element4 SUMMUM 190

Element4 SUMMUM 190 Installation Guide - Dutch - 38 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info