Chapter 6
INSTALLATION MANUAL |
6 INSTALLATION REQUIREMENTS
This product has been designed to be installed into a plaster board, or
existing masonry chimney breast.
Please seek advice from a professional, with reference to the structural
integrity of the installation site.
If the product is to be installed into a open chimney or ue, it is
important that the chimney/ue is blocked o to prevent any up/down
draughts and falling debris which could restrict and alter the airow to
the product.
It is also important to ensure that the product has a minimum internal
clearance directly above and below the product of 100mm, this is to
ensure that the product can circulate the required airow for the heater
unit. This is most important for the Elite 60I e as it's top surface can get
hot.
The product should never be sealed into a opening with the use of
silicones or adhesives as this can also alter the airow and hinder any
further servicing of the product.
Figure.6.1 | Beware, top of Elite 60I e can get hot
6�1 HEATER UNIT CUT OUT
This is a safety feature to safe guard against further damage to the
product.
If the airow is restricted the heater will automatically turn o. This can
occur due to incorrect installation or obstruction. To reset the heater
function;
Isolate from main power supply
Leave product to cool
After suitable cooling down period, remove the obstruction if
obstructed and check installation
After 10 minutes the thermo switch (cut-out) in the heater will
reset.
Please note: that both the eect fan and heater fan omit a low decibel
noise, both of which are normal operating characteristics.
6�2 SERVICING
Only a competent person should service this appliance. This appliance
must be serviced every 12 months.
Warning: Before carrying out any repairs or servicing, ensure that the
power supply cord is removed from the mains supply.
7 INSTALLATION METHOD
In all Element4 replaces, a free space of 100mm at least 50mm
must be maintained immediately above and below the main housing
for good air circulation. (Failure to do so may cause problems for the
heating and ame function).
Each Element4 replace is supplied with one or more wall mounting
brackets.
Determine the height at which the nished Element4 replace should
be positioned in relation to the oor level.
Note: The minimum distance to the oor is 300 mm
Attach the wall bracket to the wall, making sure that you use the correct
fasteners that match the respective wall - hollow or solid.
Hang the Element4 replace on the bracket and secure it in place with
the wall bracket at the top of the replace.
Insert the plug of the IEC-compliant power cable into the IEC-compliant
socket and ensure that it is rmly pushed.
Construct the hollow installation space for the electric re in the
desired dimensions. It is important that you take into account the
nished front when determining the depth of the frame construction.
It is important that a header/lintel is also placed at the desired height,
so that the weight of the wall made will not come to rest on the
appliance.
Make the cut in the plasterboard / nishing plate and install the
replace, making sure that the plaster board edges connect to the
inside of the cut in the plate.
Warning: In order to avoid a hazard due to inadvertent resetting of
the thermal cut-out, this appliance must not be supplied through an
external switching device, such as a timer, or connected to a circuit
that is regularly switched on and o by the utility.
7�1 PRODUCT SIZE
Theproduct dimensions can be found in APPENDIX BAPPENDIX B
It is also important to ensure that the product has a minimum clearance
around it of 15mm, this is to ensure that the product can circulate the
required airow to the heater unit.
The product should never be sealed into an opening with the use
of silicones or adhesives as this can alter the airow and hinder any
further servicing of the product.
Please refer to technical specication table for further information, with
reference to measurements.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Element4 Elite-E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Element4 Elite-E in the language / languages: English as an attachment in your email.

The manual is 3.9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Element4 Elite-E

Element4 Elite-E Installation Guide - German - 28 pages

Element4 Elite-E Installation Guide - Dutch - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info