DESCRIPTION
PT712-EI is a digital thermostat with a room and fl oor sensor, specially designed for electric fl oor heating
control. The internal-external sensor combination enables the regulation of:
1) fl oor temperature (external sensor) - suitable, for instance, for bathrooms where a warm fl oor is
desirable, irrespective of the room temperature;
2) room temperature (internal sensor) - when comfortable room temperature is required;
3) combined (both sensors) - the internal sensor scans the room temperature, while the
external one monitors the maximum fl oor temperature;
comfortable room temperature is required, however, with
simultaneous monitoring of the fl oor temperat
(suitable for wooden
and laminated fl oors).
Another advantage is simple installation in the KU/KP68 junction boxes by means of the PLUG-IN
system, as well as the possibility of setting 2 weekly programs with 6 temperature changes per day.
INSTALLATION AND LOCATION
Install the thermostat in a suitable place (minimum height of 1.2-1.5 m above the fl oor) where its operation
will not be affected by direct hot/cold air fl ow, sunshine or other disturbing infl uences. Do not mount the
thermostat on an exterior wall either. In rooms with increased humidity (bathroom, kitchen), observe valid
standards and install the thermostat as far from the bathtub, shower, basin or sink as possible.
The external fl oor sensor
(type CT04-10k, CYXY 2 x 0.5 mm, 10 k:, lenght 3 m, PVC plastic case)
must be located in a fl exible plastic tube embedded in the fl oor, as near to the surface as possible. The
tube must be sealed and protected against in-leak of building materials so that the fl oor sensor can be
replaced easily, if need be. It must not run parallel with power conductors! It can be extended to
a maximum length of 30 metres. The installation can only be done by a properly qualifi ed person!
Disconnect power supply before installation!
1) Switch off the main circuit breaker.
2) Check that the junction box is placed parallel with the wall.
3) Separate the power part of the thermostat from its microprocessor (main) part; see Fig. 1.
4) Pull the connecting terminals out of the thermostat rear part, see Fig. 2.
5) Connect conductors to the terminals acc. to the wiring diagram below, see Fig. 3.
6) Insert the terminals into the thermostat terminals and fasten the power part to the junction
box, see Fig. 4 and 5.
7) Insert the main part connector into the power part and push it; the metal springs must
t in the given holes, see Fig. 6 and 7.
8) Switch on the main circuit breaker; the thermostat is ready for operation. LCD backlight becomes active only
after charging the backup battery (up to 24 hours).
9) Set the constant 4 (page 6) according to the load, this could cause an inaccurate display of the current
temperature.
Note: We recommend you test correct connection after installation, see the TEST function (page 7).
Wiring diagram:
Fig. 1
When using the low tariff
L‘ = disconnected phase
power part main part
PULLPULL
connecting
terminals
HEATING
HEATING
NTC 10k NTC 10k
* P= max. 2760 W
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elektrobock PT 712EI at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elektrobock PT 712EI in the language / languages: English as an attachment in your email.

The manual is 0,27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Elektrobock PT 712EI

Elektrobock PT 712EI User Manual - German - 8 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info