600921
5
Zoom out
Zoom in
Previous page
1/8
Next page
DIGITAL
THERMOSTAT
FOR FLOOR HEATING
MADE IN CZECH REPUBLIC
including external sensor
backup in case of voltage failure > 100 hours
•direct installation on junction box
•well-arranged backlit display
VENUS switch design
PT712-EIPT712-EI
NL
COM NO
NL
COM NO
L'
2
DESCRIPTION
PT712-EI is a digital thermostat with a room and fl oor sensor, specially designed for electric fl oor heating
control. The internal-external sensor combination enables the regulation of:
1) fl oor temperature (external sensor) - suitable, for instance, for bathrooms where a warm fl oor is
desirable, irrespective of the room temperature;
2) room temperature (internal sensor) - when comfortable room temperature is required;
3) combined (both sensors) - the internal sensor scans the room temperature, while the
external one monitors the maximum fl oor temperature;
comfortable room temperature is required, however, with
simultaneous monitoring of the fl oor temperat
(suitable for wooden
and laminated fl oors).
Another advantage is simple installation in the KU/KP68 junction boxes by means of the PLUG-IN
system, as well as the possibility of setting 2 weekly programs with 6 temperature changes per day.
INSTALLATION AND LOCATION
Install the thermostat in a suitable place (minimum height of 1.2-1.5 m above the fl oor) where its operation
will not be affected by direct hot/cold air fl ow, sunshine or other disturbing infl uences. Do not mount the
thermostat on an exterior wall either. In rooms with increased humidity (bathroom, kitchen), observe valid
standards and install the thermostat as far from the bathtub, shower, basin or sink as possible.
The external fl oor sensor
(type CT04-10k, CYXY 2 x 0.5 mm, 10 k:, lenght 3 m, PVC plastic case)
must be located in a fl exible plastic tube embedded in the fl oor, as near to the surface as possible. The
tube must be sealed and protected against in-leak of building materials so that the fl oor sensor can be
replaced easily, if need be. It must not run parallel with power conductors! It can be extended to
a maximum length of 30 metres. The installation can only be done by a properly qualifi ed person!
Disconnect power supply before installation!
1) Switch off the main circuit breaker.
2) Check that the junction box is placed parallel with the wall.
3) Separate the power part of the thermostat from its microprocessor (main) part; see Fig. 1.
4) Pull the connecting terminals out of the thermostat rear part, see Fig. 2.
5) Connect conductors to the terminals acc. to the wiring diagram below, see Fig. 3.
6) Insert the terminals into the thermostat terminals and fasten the power part to the junction
box, see Fig. 4 and 5.
7) Insert the main part connector into the power part and push it; the metal springs must
t in the given holes, see Fig. 6 and 7.
8) Switch on the main circuit breaker; the thermostat is ready for operation. LCD backlight becomes active only
after charging the backup battery (up to 24 hours).
9) Set the constant 4 (page 6) according to the load, this could cause an inaccurate display of the current
temperature.
Note: We recommend you test correct connection after installation, see the TEST function (page 7).
Wiring diagram:
Fig. 1
When using the low tariff
L‘ = disconnected phase
power part main part
PULLPULL
connecting
terminals
HEATING
HEATING
NTC 10k NTC 10k
* P= max. 2760 W
MENU
3
DESCRIPTION OF LCD AND CONTROL BUTTONS
1, Current date (in the Prog mode, selection of number of days for
programming)
2, Operating modes: OFF/PROG/AUTO/MANU/case=HOLIDAY
3, Current room temperature
4, Indication of room temp. measurement by the exter. sensor.
5, Heating on indication
6, Button lock indication
7, CLOC mode indication (current date and time setting)
8, Required temperature and current time display / listing of operating
modes (this line is explained in detail with every mode)
9, Battery supply indication (in case of 230V/50Hz voltage failure,
it is functional only after 1 day of operation, when the backup
battery is charged!)
10, Indication of setting the external sensor as the fl oor one
11, Anti-freeze temperature of 3 °C
MENU
button:
short press = opens the main menu and
confi rmation (ENTER)
long press (approx. 3 sec.) = back from the
main menu
/ button:
basic mode = opens info
main menu =browse and set current values
simultaneous press of the
MENU
and
buttons (in basic mode) = key lock
simultaneous press of the
MENU
and
buttons (in basic mode) = key unlock
simultaneous press of the
MENU
and /
buttons (in main menu) = return to basic mode
Note: The LCD backlight is activated by pres-
sing any button!
Fig. 2 Fig. 3 Fig. 4
Fig. 5
Fig. 6
Fig. 7
NL
NO COM
PULL out the connecting terminals.
Connect according to the wiring diagram.
PUSH the connecting
terminals in.
Screw the power part to
the junction box.
Connector and holes
for metal springs.
PUSH the
main part
onto the
power part.
9
4
OPERATING MODES
By pressing any button, you activate the display backlight (if the backlight is not working,
batteries are not charged and it is necessary to recharge the thermostat about 1 days).
Next, pressing the
MENU
button briefl y, you enter the main menu, in which you can choose
the operating modes.
AUTO
The thermostat works according to the preset weekly program.
Press the
MENU
button and choose the AUTO mode with
the / buttons. Press
MENU
to confi rm.
MANU
The thermostat works according to the preset temperature, which
remains constant until the next manual change.
Press the
MENU
button and choose the MANU mode with the
/ buttons. Press
MENU
to confi rm.
(default setting of 21°C)
OFF
The thermostat is switched off until the next manual change.
Press the
MENU
button and choose the OFF mode with the
/ buttons. Press
MENU
to confi rm.
The thermostat maintains the preset temperature until the given
date and time. When the preset period expires, it returns to the
AUTO or MANU mode automatically.
Press the
MENU
button and choose the AUTO or MANU mode with
the / buttons. Press
MENU
to confi rm.
Press the
MENU
button again and choose the mode with the
/ buttons. Press
MENU
to confi rm.
The temperature value fl ashes on the LCD. Set the desired
temperature with the / buttons and press
MENU
to confi rm
it; next, set the hour, minute, day, month and year when your
holiday ends; confi rm each setting by pressing
MENU
.
After setting, the device automatically switches to the HOLIDAY
mode within 1 minute! The holiday end date appears on the
display!
HOLIDAY
5
CLOC
Setting the current date and time.
Press the
MENU
button and choose the CLOC mode with
the / buttons. Press
MENU
to confi rm.
The current hour value fl ashes on the LCD. Set the current hour and
confi rm it by pressing
MENU
then, set the minutes and seconds; next,
the current date appears; again, set the current day, month and year
with the / buttons. Confi rm each setting by pressing
MENU
.
PROG
Setting of weekly programs (2 weekly programs are available,
each with 6 changes per day).
Press the
MENU
button and choose the PROG mode with
the / buttons. Press
MENU
to confi rm.
P1 (the fi rst weekly program) ashes on the LCD; press
MENU
to confi rm it;
The programmed day number fl ashes on the LCD, choose one
of the options with the / buttons (you can program “day
after day”, or Mon-Fri, Sat-Sun or Mon-Sun). Press
MENU
to con-
rm your choice. The display shows U1 for setting the fi rst tem-
perature change; set the temperature with the / buttons
and confi rm with the
MENU
button. Set the switching time with
the / buttons and confi rm with the
MENU
button again.
The display shows U2 for setting the second temperature
change. Follow the procedure for the fi rst temperature change.
In this way, you can set up to 6 temperature changes per day. To
return to the basic mode, press the
MENU
and / buttons
simultaneously.
CONST
Setting of the regulation parameters.
Press the
MENU
button and choose the CONST mode with the /
buttons. Press
MENU
to confi rm it. The fi rst parameter appears on the LCD.
1
2
MINIMUM SWITCH-ON TIME IN HYSTERESIS
HYSTERESIS
The hysteresis can be set from 0.1 to 5 °C. If, for example, the
hysteresis is 1 °C and the required temperature is 20 °C, the ther-
mostat switches off at 20 °C and switches on again at 19 °C.
Set the pertinent value with the
/ buttons and press
MENU
to confi rm.
Here, you can set the minimum switch-on time of the heating device in
hysteresis in minutes. It can be set within the range 1 to 5 minutes.
Set the pertinent value with the
/ buttons and press
MENU
to confi rm.
6
Make your choice with the / buttons according to the appli-
cation type and press
MENU
to confi rm.
- - - The external sensor, if connected, measures the temperature
at the point of location (suitable, for instance, for bathrooms,
where you wish to have a warm fl oor irrespective of the
room temperature);
15…99,5°C The external sensor, if connected, monitors the fl oor
temperature; the maximum permissible temperature is set
for the fl oor heating (you regulate with the room
temperature, monitoring the fl oor temperature
at the same time).
If the preset limit temperature is exceeded, the thermostat is switched off irrespective of
the room temperature, and the STOP message appears on the LCD. Once the external
sensor temperature drops by 0.5 °C, the heating device is switched on again.
If the sensor is not connected or it is defective, the C2.Err error message appears on the
LCD.
After connecting the external sensor, it is NECESSARY
to RESET the device (see parameter 5)!
This use of the sensor is indicated by the sign on the LCD.
The fl oor (monitoring) sensor is indicated by the sign on the LCD.
3
EXTERNAL SENSOR SELECTION
4
5
FIRMWARE VERSION / DEFAULT SETTING RECOVERY
SELECTION THE POWER OF CONNECTED DEVICE
Set the input of the connected device in watts.
Can be selected in the range from 0 to 2700 W in steps of
100 W, maximum power is 2760 W. Choosing this constant is
achieved more accurate regulation. For a given power starts
automatic calibration of the thermostat.
Set the value by / buttons and press the
MENU
.
Use the option 0 for : boiler, thermoelectric valve, contactor, etc. (for input power less
than 100 W).
Information on the fi rmware version. If you keep pressing the
button (approx. 3 sec), the RESET message appears briefl y
on the LCD, and the thermostat recovers the default setting!
You can exit the CONST mode at any time by simultaneously pressing the
MENU
and /
buttons (return to the basic mode).
7
OTHER FUNCTIONS
By pressing the / buttons in the basic mode, you can view the following information:
In the basic mode, press the
/ buttons. The LCD shows
the required temperature value for the current operating mode
(it can be changed with the / buttons; in the AUTO
mode, the change is short-term – until the next change in the
program; in the MANU mode, the change is permanent).
With another press of the
MENU
button, you can switch to:
INFO
REQUIRED TEMPERATURE
This is used for quick change of the program selected in the
AUTO mode. If both P1 and P2 programs are preset, they can be
changed, after a week for example, with the / buttons.
With another press of the
MENU
button, you can switch to:
SELECTED PROGRAM NUMBER - in the AUTO mode only
OPERATING HOURS
The LCD shows the operating hour value of the heating
device. You can clear it by pressing the button.
With another press of the
MENU
button, you can switch to:
TEST
The LCD shows the TEST message, which can be switched to
the LCD test on/off with the / buttons (the output relay
will be switched on/off several times).
We recommend using this function for the fi rst use of the
thermostat to check its correct connection!
With another press of the
MENU
button, you can view prior information
if the external sensor is connected as the fl oor (monitoring) one:
CURRENT TEMPERATURE OF THE FLOOR SENSOR
The LCD shows the current temperature value of the fl oor sensor.
To return to the basic mode, keep pressing the
MENU
button (for approx. 3 sec)!
In the basic mode, simultaneously press the
MENU
and buttons, the buttons will lock (the
key sign on the LCD). Unlocking can be done by simultaneously pressing the
MENU
and
buttons.
LOCK
Pb
LEAD FREE
in compliance with RoHS
81
47
81
ELEKTROBOCK CZ s.r.o.
Blanenská 1763
Kuřim 664 34
Tel.: +420 541 230 216
MADE IN CZECH REPUBLIC
In case of warranty or
post-warrant service,
send the product to
the manufacturer’s
address.
WARRANTY CERTIFICATE
(a 2-year warranty is granted for the product)
Product number:
Date of sale:
Shop stamp:
Checked by:
Technical parameters
Power supply 230 V/ 50 Hz
Number of adjustable temp. 6 different temp. per every day
Hysteresis 0.1 to 5°C
Minimum program time 10 minutes
Adjustable temp. range +3°C to 99.5°C
Temperature setting by 0.5°C
Minimum indication step 0.1°C
Measurement accuracy ± 0,5°C
Backup battery more than 100 hours
Protection class IP20
Protection rate II
Output max.12A (potential-free contacts)
Working temperature 0°C to +40°C
Dimensions:
Properties:
2 weekly programs with 6 temperature
changes per day
backlit display
HYSTERESIS setting option
heating source minimum switch-on time
setting
operating modes:
AUTO/MANU/OFF/HOLIDAY
maximum fl oor temperature limit value
setting
quick change of the required temperature
operating hours information
child lock – locking of keys
backup in case of voltage failure for
more than 100 hours
simple installation (PLUG-IN system)
elegant design of the VENUS switch series
Used for the control of electric fl oor heating (heating cables, mats, foils).
It enables regulation according to the room temperature with possible fl o-
or temperature monitoring. Using the thermostat, you can reduce heating
costs and, at the same time, achieve thermal comfort at the given time.
included in the package
type CT04-10k,
CYXY 2 x 0.5 mm,
10 k:, length 3 m,
PVC plastic case
External sensor:
Another advantage:
The thermostat can be located in the multiple frame of the
VENUS design.
The PLUG-IN system = quick and easy installation. The thermo-
stat is divided into the power part and the main microprocessor
part, which can be connected by simple insertion of the intercon-
necting terminals. The input conductors (or external sensor) are
connected to the power part terminals and fastened to the juncti-
on box; then you can simply fi nish the installation by inserting the
main part onto the power part.
www.elbock.cz
DIGITAL THERMOSTAT PT712-EIPT712-EI
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elektrobock PT 712 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elektrobock PT 712 in the language / languages: English as an attachment in your email.

The manual is 0,27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Elektrobock PT 712

Elektrobock PT 712 User Manual - German - 8 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info