646321
37
Zoom out
Zoom in
Previous page
1/66
Next page
ULTRAMAX PB 65 - 120
37 L290 ©MHS Boilers 13/12/2010
11.0 Parameterisation for End User
11.2 Parameterisation
Item
AGU2.311
Parameter
Factory
Setting
Adjustment
Range
Units
Function
Time / Date
1
P1
0…23:59
hh:mm
Time
2
P2
1-7
Current day of the week (1=Monday)
Target Values
4
P5
16
20-85
Room temperature reduced target value
Timer Program HC1 (Heating Circuit 1)
P10
0-9
Day of the week timer setting HC1 (0; 1-7; 1-5;6-7)
5
P11
06:00
00:00…24:00
hh:mm
Timer program HC1 Timer ON = Phase 1
6
P12
22:00
00:00…24:00
hh:mm
Timer program HC1 Timer OFF = Phase 1
7
P13
--
00:00…24:00
hh:mm
Timer program HC1 Timer ON = Phase 2
8
P14
--
00:00…24:00
hh:mm
Timer program HC1 Timer OFF = Phase 2
9
P15
--
00:00…24:00
hh:mm
Timer program HC1 Timer ON = Phase 3
10
P16
--
00:00…24:00
hh:mm
Timer program HC1 Timer OFF = Phase 3
Timer Program HC2 (Heating Circuit 2)
11
P20
0-9
Day of the week timer setting HC2 (0; 1-7; 1-5; 6-7)
12
P21
06:00
00:00…24:00
hh:mm
Timer program HC2 Timer ON = Phase 1
13
P22
22:0
00:00…24:00
hh:mm
Timer program HC2 Timer OFF = Phase 1
14
P23
--
00:00…24:00
hh:mm
Timer program HC2 Timer ON = Phase 2
15
P24
--
00:00…24:00
hh:mm
Timer program HC2 Timer OFF = Phase 2
16
P25
--
00:00…24:00
hh:mm
Timer program HC2 Timer ON = Phase 3
17
P26
--
00:00…24:00
Timer program HC2 Timer OFF = Phase 3
Timer Program DRW as Domestic Use Loading Program for Drinking Water
18
P30
0-9
Day of the week timer setting HC2 (0; 1-7; 1-5; 6-7)
19
P31
06:00
00:00…24:00
hh:mm
Timer program DRW Timer ON = Phase 1
20
P32
22:00
00:00…24:00
hh:mm
Timer program DRW Timer OFF = Phase 1
21
P33
--
00:00…24:00
hh:mm
Timer program DRW Timer ON = Phase 2
22
P34
--
00:00…24:00
hh:mm
Timer program DRW Timer OFF = Phase 2
23
P35
--
00:00…24:00
hh:mm
Timer program DRW Timer ON = Phase 3
24
P36
--
00:00…24:00
hh:mm
Timer program DRW Timer OFF = Phase 3
25
P45
No
No/Yes
Standard timer program for HC1, HC2 and DRW
Parameter Setting
26
516
30
8-30
°C
Summer/Winter switch temperature
27
520
10
0-10
K
Drop amount for room target temperature with timers
28
532
15
1-40
Heating characteristic HC1
29
533
10
1-40
Heating characteristic HC2
30
534
0
-31 +31
K
Room target value correction HC1
31
535
0
-31 +31
K
Room target value correction HC2
32
629
0
End user may acknowledge a pending maintenance message
33
726
0
Contains a numeric maintenance code
34
727
50b
Internal diagnostics code
37


Need help? Post your question in this forum.

Forumrules
1

Forum

elco-ultramax-pb-65---120

Reset search

  • What is the fault code 153 on ultramax pb 120 boiler Submitted on 10-12-2021 at 10:53

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elco Ultramax PB 65 - 120 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elco Ultramax PB 65 - 120 in the language / languages: English as an attachment in your email.

The manual is 3,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info