25 L290 ©MHS Boilers 13/12/2010
8.0 Mounting the exterior temperature sensor
This sensor is not pre-wired.
Installation site:
Minimum of 2m above ground, on the north wall of the building
Make sure that the sensor is not affected by fireplaces, windows etc
Installation type:
Turn the sensor such that the wires exit the casing at the bottom
Conduit length:
Maximum of 100m when using NYM 3 x 1 mm² or H05W-F3 x 1 mm²
9.0 Electrical Installation
WARNING THIS APPLIANCE MUST BE EARTHED IN ACCORDANCE WITH BS 7671 and IEE
REGULATIONS
9.1 General Notes
The Ultramax PB is supplied as standard with electronic operating and flame ionisation safety controls with a
specially designed microprocessor at the heart of the system.
The boiler is pre-wired as shown and all connections can be made on the terminal strips (one low voltage 25
vac and one mains voltage 240 v ac).
Electrical specialists should perform the electrical installation and connections to the appliance.
54-55 Safety Interlock Volt Free
(Must be wired in series with the low pressure gas
switch please see below)
52-53 Room thermostat
Volt Free
56-57 NOT USED
50-51 QAA 73
Low pressure
gas switch
Volt free Safety
Interlock Circuit
55
54
Safety Interlock Volt Free
(Must be wired in series with the low pressure gas
switch)
25


Need help? Post your question in this forum.

Forumrules
1

Forum

elco-ultramax-pb-65---120

Reset search

  • What is the fault code 153 on ultramax pb 120 boiler Submitted on 10-12-2021 at 10:53

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elco Ultramax PB 65 - 120 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elco Ultramax PB 65 - 120 in the language / languages: English as an attachment in your email.

The manual is 3,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info