Menu: Heating circuits
For heating circuits, there are various
functions available which can be
individually set for each heating circuit.
Room setpoint
Room temperature
The room temperature can be shifted
according to different setpoints. These
setpoints become active depending on
the selected operating mode, thus
producing different temperature levels
in the rooms. The ranges of adjustable
setpoints result from the
interdependencies, as this is shown in
the following diagram.
Frost protection
In protection mode, the room
temperature is prevented from falling
below a certain level. This means that
the frost protection setpoint of the
room temperature will be maintained.
Heating curve
The heating curve is used to
generate the flow temperature
setpoint, shich is used to maintain a
certain flow temperature level
depending on the prevailing weather
conditions. The heating curve can
be adjusted with a number of
settings, thus matching heat output
and room temperature to individual
needs.
Line no.
Operating line
Factory setting
HC1
HC2
710
1010
Comfort setpoint
20°C
712
1012
Reduced setpoint
16°C
714
1014
Frost protection
4°C
TRF
TRKmax Comfort setpoint maximum
TRK Comfort setpoint
TRR Reduced setpoint
TRF Frost protection setpoints
Line no.
Operating line
Factory setting
HC1
HC2
720
-
Heating curve slope
1,5
-
1020
Heating curve slope
0,8
721
1021
Heating curve displacement
0
726
1026
Heating curve adaption
Off
22
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elco Thision S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elco Thision S in the language / languages: English as an attachment in your email.

The manual is 2,06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Elco Thision S

Elco Thision S User Manual - German - 20 pages

Elco Thision S User Manual - Dutch - 21 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info