577299
11
Zoom out
Zoom in
Previous page
1/52
Next page
Parameters professional installer
Menu
Line no.
Operating line
Unit
Min.
Max
Factory setting
Holidays HC1
642
Period Start Day / Month
tt.MM
01.01
31.12
--.--
--.--
643
Periode End Day / Month
tt.MM
01.01
31.12
--.--
648
Operating level
-
Frost protection, Reduced
Frost protection
Holidays HC2
(when activated)
652
Period Start Day / Month
tt.MM
01.01
31.12
--.--
653
Periode End Day / Month
tt.MM
01.01
31.12
--.--
658
Operating level
-
Frost protection, Reduced
Frost protection
HC 1
710
Comfort setpoint
°C
Value from Line no. 712
35
20.0
712
Reduced setpoint
°C
Value from Line no. 714
Value from Line no. 710
16.0
714
Frost protection setpoint
°C
4
Value from Line no. 712
4
720
Heating curve slope
-
0.10
4.00
1.50
721
Heating curve parallel
displacement
°C
-4.5
4.5
0.0
726
Heating curve adaption
°C
Off, On
Off
730
Summer/winter heating limit
°C
---/8
30
20
732
24-hour heating limit
°C
---/-10
10
-3
740
Flow temp setpoint min
°C
8
Value from Line no. 741
8
741
Flow temp setpoint max
°C
Value from Line no. 740
80
80
750
Room influence
%
---/0
100
20
760
Room temp limitation
°C
---/0.5
4
1
770
Boost heating
°C
---/0
20
2°C
780
Quick setback
-
Off, Down to Reduced setpoint,
Down to Frost protection setpoint
Down to Reduced
setpoint
790
Optimum start control max
min
0
360
0
791
Optimum Stop control max
min
0
360
0
800
Reduced setp increase start
°C
---/30
10
---
801
Reduced setp increase end
°C
-30
Value from Line no. 800
-15
850
Floor curing function
-
Off, Functional heating, Curing heating,
Functional/Curing heating, Manually
Off
851
Floor curing setp manually
°C
0
95
25
884
Speed design point
-
1
50
9-13 kW = 16
17-25 kW =
19
35-50 kW =
24
885
Pump PWM min
%
10
100
40 %
886
Standard outside temp
°C
-50
+20
- 15°C
887
Flow temp setp standard OT
°C
20
90
75 °C
888
Curve readj at 50% speed
%
0
100
40
894
dT differential standard OT
°C
2.5
20
20
895
dT differential max
°C
2.5
35
20
11
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elco Thision S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elco Thision S in the language / languages: English as an attachment in your email.

The manual is 2,06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Elco Thision S

Elco Thision S User Manual - German - 20 pages

Elco Thision S User Manual - Dutch - 21 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info