5
Operating elements
Operating elements
Filling and de-aeration
Legend:
A On/Off switch
B Back button (ESC)
C Room temperature control button
D Conrmation button (OK)
E Function button for manual
operation
F Chimney sweep function button
G Information button
H Reset button
I Operation mode button for heating
circuit(s)
L Display
M Operating mode button for DHW
Operating mode button for DHW (M)
For switching on the DHW preparation
(Bar under the water crane in the
display)
Operation mode button for heating
circuit(s) (I)
For setting 4 different operating modes
for heating
Automatic clock: Automatic operation
according to timer program
Sun 24 hr: Heating at comfort target
value
Moon 24 hr: Heating at reduced value
Protection mode: Heating switched off -
frost protection active
Display (L)
Information button (G)
Retrieval of the following information,
without inuence on the control
processes:
Temperatures, operating condition of
the heating facility/DHW, error reports
Room temperature control button
(C)
- For changing the room comfort
temperature
- With this rotating button, settings
can be selected and changed
during programming.
M
A
H
B C D E F
I
L
G
Conrmation button OK (D)
Back button ESC (B)
These two buttons are needed in
combination with the large rotating
button (- +) for the programming
and conguration of the control unit.
Settings, which cannot be changed
through the control elements, are
provided by means of programming.
By pushing the ESC button you always
go one step backward, whereby
modied values are not taken over.
To reach the next operating level, or
to store the changed values, you must
push the OK button.
Manual operation function button (E)
By pushing this button, the control
unit is set to manual mode, whereby
all pumps are running, the mixer is
no longer controlled and the burner is
set to 60°C. (Indicated by the spanner
symbol)
Chimney sweep function button (F)
Push this button shortly, to put the
boiler in the operating mode for
measuring emissions; renewed
pushing of the button deactivates
this function, or it is automatically
deactivated after 15 minutes (indicated
by the spanner symbol).
May only be operated by the chimney
sweep!
Reset button (H)
By pressing this button shortly, the
locked condition of the burner is
deactivated.
On/Off switch (A)
Position 0:
The entire facility and all connected
electrical components are without
electrical power. A protection against
frost is not ensured.
Position I:
The entire facility and all connected
electrical components are ready for
operation.
Filling and de-aeration of the
THISION S PLUS and the heating
facility
The heating facility is lled according to
the standard method.
The facility must have been deaerated,
both on the heating and the warm
water side.
The water pressure can be read off
in bar, either on the analog pressure
indicator or via the information button.
The boiler is ready for operation, as
soon as the heating facility has been
lled and deaerated.
After an appropriate period, the water
pressure should be checked and, if
necessary, water should be topped up.
(Note: Before topping up the water, rst
ll the hose with water, which prevents
the entry of air into the heating system).
Use the pump de-aeration function to
remove all air from the pump and the
boiler: Hold down the E button for more
than 3 seconds. This function runs for
approximately 16 minutes.
During the initial commissioning, or
after lling or topping up the heating
facility, always rst activate the de-
aeration function.
45


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elco THISION S PLUS Combi at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elco THISION S PLUS Combi in the language / languages: English, German, Italian as an attachment in your email.

The manual is 1,21 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info