Installa on
18
Air/Flue gas system
Combus on air
drawn from the
room
B23 External ue gas exhaust. Air drawn from the room
Combus on
air intake from
outside
C13
Air/exhaust gas rou ng through outside wall in the same
pressure range.
Exhaust gas/fresh air supply system through outside wall.
The Terminal outlets from separate combus on and air supply circuits
shall t inside a square of 50 cm for boilers with a heat input to 70 kW
and 100 cm with a heat input from 70 up to 100 kW.
C33
Flue gas exhaust and air suc on duct from outside with roof terminal
in the same range of pressure.
The Terminal outlets from separate combus on and air supply circuits
shall t inside a square of 50 cm and distance between the planes of
the two ore ces shall be less than 50cm for boilers with a heat input
below 70 kW.
A square of 100 cm and distance between the planes of the two or-
e ces shall be less than 100 cm with a heat input above 70 kW.
C43 Individual or shared ue gas exhaust and air suc on through ue duct-
ing built into the building.
C53 Flue gas exhaust leading outside and air suc on duct through external
wall not in the same range of pressure
C63
Air and exhaust connec on to separate tested and supplied
air / exhaust pipes.
Basement / oor installa on.
Air and exhaust ven ng via exterior wall.
Exhaust ven ng through heat insulated exhaust pipe or moisture
resistant pipe.
Exhaust line (standing air layer) at exterior wall.
The terminals for the supply of combus on air and for the evacua on
of combus on products shall not be installed on opposite
walls of the building.
C83 Flue gas exhaust through individual or shared ue duc ng built into
the building. Air suc on through external wall
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elco THISION L EVO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elco THISION L EVO in the language / languages: English as an attachment in your email.

The manual is 8,12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info