Service and Maintenance
Maintenance, Service and
cleaning must be carried out by
trained and approved Personnel.
This person shall be responsible
for correct implementation of
Mantainence activities.
It is recommended that
Maintenance/Service works should be
carried out once a year. Cleaning of
the heat exchanger coils, as long
there is only minor contamination of
the coils, should be carried out at least
every 2 years.
Measuring and recording of preset
emission values
Switch off heating circuit breaker
and secure against coming on
again, or separate the appliance
on all poles from the mains
Isolate the Gas Supply
Dismantle appliance casing, bring
control panel into service position
Dismantle compressor, gas valve
and burner unit
Disconnect ignition cable. Check
ignition plugs for breaks, moisture
(damp/moist ignition plugs cause
malfunction messages - replace
ignition plugs)
Visual check of burner (if
necessary clean with brush/nylon
brush or vacuum cleaner)
Visual check of Fan and venturi
burner (if necessary clean with
brush/nylon brush or vacuum
cleaner)
Disconnect combustion chamber
insulation
Flush out heat exchanger with
pure water (remove obstinate
impurities with fine synthetic
brush and flush out)
Clean siphon and refill with water
before assembly
Check all connections of
condensate-carrying parts for
watertightness. Remove any
leaking condensate or other
dampness
Check fixing screws, replace if
necessary.
The dismantled seals for gas and
water carrying parts should be
replaced with new seals when
reassembling; this applies
especially for O rings on the gas
valve and all burner seals
Reassemble appliance ready for
operation
Open gas pipe and check for
watertightness
Switch on heating circuit breaker
Carry out function monitoring with
emissions measurement
Values according to factory
specifications, readjust if
necessary
39


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elco MHS - EURON 30 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elco MHS - EURON 30 in the language / languages: English as an attachment in your email.

The manual is 2,98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info