Service and maintenance
Monitoring and checking
General remarks
At least once a year the appliance
should undergo the following
monitoring:
1. Check seals of water pipes and if
applicable replace.
2. Check seals of gas pipes and if
applicable replace as required.
3. Visual check of condition of all
boiler components.
4. Visual check of burner.
5. Cleaning of main heat exchanger
6. Check functional efficiency of
safety system:
i.e. Temperature protection.
7. Check functional efficiency of gas
feed safety system:
Gas and flame failure
protection (ionisation)
8. For Combi Boiler monitoring of
service water production efficiency
(checking through flow and
temperature).
9. Checking general functional
efficiency of boiler.
10. Remove any oxidization on the
electrode with the aid of an emery
cloth.
11. Check correct positioning / spark
gaps of the ignition and ionisation
electrodes as per the adjacent
picture.
12. Check the combustion fan blades
for debris build up. Remove any
debris with a soft bristle brush or
compressed air.
Cleaning of stainless steel heat
exchangers
For Cleaning the interior/dry side of the
heat exchanger coils, the burner / burner
door assembly must be removed.
For cleaning you may use water, a
cleaning agent (citric acid*) and use a
non-metal brush. Afterwards flush with
water.
Note: Never Clean the Burner itself
Cleaning of the Siphon
To gain access to the siphon, unscrew
the Condense collecting glass clockwise,
which is on the bottom left of the
underside of the boiler. Allow water to
drain out safely. Pour 2 litres of clean tap
water into the heat exchanger and allow
to drain safely through to the cleaning
point.
Refit the Condense Collecting Glass and
poor a further 2 litres of clean tap water
into the heat exchanger to ensure the
siphon is full of water.
If the appliance has not been used
for a long time, the siphon must be
filled before switching on again.
It is dangerous not to refill the siphon
with water, as in this case flue gas
can escape into the atmosphere.
Function checking
After completing the maintenance
work fill the heating circuit with a
pressure of around 1,0 bar and bleed
the appliance of air.
Also fill the service water appliance.
Set the appliance in operation. If
necessary, bleed the heating
appliance again. Check the
adjustments and correct operation
of all operator, calibration and
monitoring elements.
Check that the flue gas connection is
completely sealed with no cross
contamination to the combustion air
and is functioning correctly.
* Cleaning Granules availble from
MHS Spares Department
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elco MHS - EURON 24 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elco MHS - EURON 24 in the language / languages: English as an attachment in your email.

The manual is 2,98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info