646319
12
Zoom out
Zoom in
Previous page
1/49
Next page
12 of 49
Installation
Connections
Gas connection
The Boiler is designed to belong to
the following categories for the use of
gas types.
Country
Categories
GB
II2H3P
II2H3B/P
Please check the Boiler name plate and
packaging to ensure that it is correct for
UK Operation and that the gas category
corresponds to one of the appropriate for
the UK.
The gas inlet must be manufactured and
measured according to the relevant
specific country regulations as well as the
maximum output of the equipment; check
also the correct calculation and
connection of the stop valve.
Before installation, the gas line should be
thoroughly cleaned, so that any residue
does not impair the functional efficiency
of the heating appliance.
Also ensure that the boiler is for the
correct type of gas to be used i.e. Natural
Gas or LPG (check the name plate in the
interior of the appliance).
Check the required gas pressure for
either natural gas or LPG.
Water connection
All connections for water and gas are
as per the illustration on page 8.
Ensure that the cold water main
pressure does not exceed 6 bar. If > 6
bar then a pressure limiter device must
be fitted.
The minimum pressure needed by the
appropriate devices for processing of
hot service water is about 0.2 bar.
On sizing the pipes and the heating
element of the Boiler, the residual
head pressure must be considered
depending on the required flow rate as
per the pump circulation curve (see
page 14)
With Combi Boiler (type HSG) flow
limiters are built into the water switch.
This ensures a constant flow of service
water
(EURON 24 HSG = 8 Litre/Minute
EURON 30 HSG = 10 Litre/Minute).
Underfloor heating
For underfloor heating, attach a
suitable safety thermostat to the
supply. (see page 15)
Note: High flow temperature leads to
an operating lockout of the Boiler both
in DHW and heating operation:
The error code "110" appears on the
display. Operation is resumed by
pressing RESET (6) key (see page 22),
after the flow temperature has
dropped.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elco MHS - EURON 24 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elco MHS - EURON 24 in the language / languages: English as an attachment in your email.

The manual is 2,98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info