Parametrisering verwarmingsdeskundige
Menukeuze
Bedienings
regel
Keuzemogelijkheid Eenheid Min. Max Fabrieksinstelling
5021 Transfer verhoging °C 0 30 8
Tapwater
voorraadvat
(alleen als
geactiveerd)
5050 Max laadtemperatuur °C 8 80 70
5055 Herkoelingtemperatuur °C 8 95 70
5057 Herkoeling collector - Uit, Zomer, Altijd Altijd
5060 Bedrijfssoort EL verwarm - Zomer, Altijd Altijd
5061 Vrijgave EL verwarming - 24h/dag, Klokprogramma Klokprogramma
5093 Met zonne toepassing - Ja Nee Ja
5130 Transfer strategie - Altijd, Tapwater vrijgave Altijd
Configuratie
5840 Zonne servomotor - Laadpomp, Omschakelventiel
Laadpomp
5890 Relaisuitgang ZX1 -
Geen, Circ pomp Q4,
Collectorpomp 2 Q16,
Zon servomotor buffer K8,
Zonpomp ext wiss K9
, Alarmuitgang K10, Buffer laadpomp Q11,
Bufferretourklep Y15, Vaste brndstf br. pomp Q10,
EL verw tapw K6, Warmtevraag K27
Buffer laadpomp K11
geen
5930
5931
5932
Sensoringang BX 1
Sensoringang BX 2
Sensoringang BX 3
-
Geen, 'Tapwateropnemer B3, 'Tapwateropnemer B31,
Opslagtanktemperatuur B4, Opslagtanktemperatuur B41,
Collectorsensor 2 B61, Aanv temp zonne energ B63,
Ret temp zonne energie B64, Gezam retour opnemer B73,
Vaste brndstf br. opn. B22, Tapw circ opnemer B39
geen
6085 Functie uitgang P1 -
Geen, Volgens uitgang Q5, Volgens uitgang ZX1
Geen
6097 Opnemertype collector - NTC PT 1000 NTC
6098 Correctie collectoropnemer °C -20 +20 0
6099 Collector collectoropnemer 2 °C -20 +20 0
6200 Opnemer opslaan - Ja Nee Nee
6205 Reset naar standaard param - Ja Nee Nee
6207 Boiler release K27 -
Tapwaterbuffer, opslagtank Tapwaterbuffer
6208 Excess heat dischar sensor -
Met B3, met B31, met B4, met B41, met B22, met B6
Met B3
6209 Excess heat discharge temp °C 20 90 80
6210 Swi diff excess heat disch °C 0 20 2
6220 Software-versie - 0 99.9 -
Fout
6710 Reset alarmrelais - Ja Nee
Nee
6800 Historie 1 -
alleen aanduiding
6802 Historie 2 -
6804 Historie 3 -
6806 Historie 4 -
6808 Historie 5 -
In-/uitgangstest
7705 Mod gew wrde Q5 rel test % 0 100 100
7708 Modulatiesignaal Q5 % 0 100 alleen aanduiding
7711 Mod gew wrde ZX1 rel test % 0 100 100
7712 Modulatiesignaal ZX1 % 0 100
alleen aanduiding
7750 Collectoropnemer B6 °C -28.0 350
7820 Opnemertemperatuur BX1 °C -28.0 350
7821 Opnemertemperatuur BX2 °C -28.0 350
7822 Opnemertemperatuur BX3 °C -28.0 350
7842 Puls teller H1 - 0 65535
Status
8003 Status tapwater -
verscheidene statusmeldingen
8007 Status zonne-energie -
8008 Status houtketel -
8010 Status opslagtank -
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elco LOGON B SOL Zonneregelaar at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elco LOGON B SOL Zonneregelaar in the language / languages: Dutch as an attachment in your email.

The manual is 3,16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email