• Cut the cables so that they protrude from the guide by about 5 mm, insert the guide in its plug and crimp
with the specially provided tool.
Plug
8
1
~ 5 mm
8
1
• Make sure that the grey sheath stays inside the plug. This type of connection will NOT guarantee double
insulation.
• Connect one end of the Ethernet cable to the POE switch of the system and the other end to the LAN
connector of the device.
3.1. DISTANCES AND WIRE CROSS-SECTION AREAS
Type of connectionMax distanceMin - max section
Floor call30 m0,5 - 1 mm2
Panic Alarm30 m0,5 - 1 mm2
Call repetition 30 m0,5 - 1 mm2
LAN100 mCAT5e (#)
Wires with cross-section area of 0.5 mm2 or larger must comply with IEC 60332-1-2; wires with
cross section area smaller than 0.5 mm2 must comply with IEC 60332-2-2.
(#) To ensure operation of the video door phone at maximum distances, the wire must be in Category 5e
and the section of the twisted pairs must be AWG24.
The maximum resistance of the individual wire must not exceed 10ohm/100m.
The wire must comply with the following standards:
- EIA/TIA 568-B.2 or EIA/TIA 568-C.2
- EN50288 3-1
- IEC 61156-5
The connection between the IP video door phone and POE switch must be made using a single wire
without the use of additional patch cords.
4. DEVICE CONFIGURATION
To congure the device, see the technical system manual in the Technical Manuals / Communication /
Ipercom System section on the www.urmet.com website.
5. TECHNICAL SPECIFICATIONS
Power voltage: ...............................................................................................................................37 - 54 V
Max. consumption: .................................................................................................................................4,5 W
Terminal output S+, S- .........................................................................................................25 mA @ 24V
Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.
Product:
Forumrules
To achieve meaningful questions, we apply the following rules:
First, read the manual;
Check if your question has been asked previously;
Try to ask your question as clearly as possible;
Did you already try to solve the problem? Please mention this;
Is your problem solved by a visitor then let him/her know in this forum;
To give a response to a question or answer, do not use this form but click on the button 'reply to this question';
Your question will be posted here and emailed to our subscribers. Therefore, avoid filling in personal details.
Register
Register getting emails for Elbo 1761 Urmet VOG5 IP at:
new questions and answers
new manuals
You will receive an email to register for one or both of the options.
Get your user manual by e-mail
Enter your email address to receive the manual of Elbo 1761 Urmet VOG5 IP in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.
The manual is 1.5 mb in size.
You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.
If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.
The email address you have provided is not correct.
Please check the email address and correct it.
Your question is posted on this page
Would you like to receive an email when new answers and questions are posted? Please enter your email address.