El aparato cumple con los requerimientos estipulados en la Directriz CE para
productos médicos 93/42/EC.
Pieza de aplicación tipo BF
Elimine el aparato de acuerdo con la Directiva 2002/96/CE sobre Residuoa
de aparatos eléctricos y electrónicos (WEEE = Waste Electrical and Electronic
Equipment).
Fabricado conforme a estándares internacionales
Pude estar sujeto a cambios sin previo aviso
Por favor, lea detenidamente este folleto
antes de usar el termómetro.
Datos técnicos
ES
El botón Scan
La punta de medición
Lente
La tapa protectora
Visor LCD
ON/MEM
1. Rango de medición de temperatura:
Mediciones en la “zona de frente u oído”: 34~42.2°C (93.2~108°F), Uso de exploración:
-22~80°C (-7.6~176°F)
2. Temperatura de uso: 10~40°C (50~104°F).
3. Temperatura de almacenaje: -20~50°C (-4~122°F), humedad relativa≤85%.
La temperatura de transporte debe ser inferior a 70ºC, humedad relativa ≤95%.
4. Cumple con ASTM E1965-98, EN12470-5:2003 Termómetros clínicos Parte 5: Salida
de termómetros de oído por infrarrojos (valores máximos), Normas de
seguridad IEC/EN60601-1-2(EMC), IEC/EN60601-1.
5. Desviaciones
Con mediciones en el oído: +/-0.2°C (0.4°F) en un rango de 35.5~42°C (95.9~107.6°F),
+/-0.3°C (0.5°F) fuera de este rango.
En modo exploración +/-0.3°C (0.5°F) en un rango de 22~42.2°C (71.6~108°F),
+/-4% o +/-2°C (4°F) fuera de este rango — el valor superior es decisivo.
6. Ubicaciones de guardado de alarma de ebre para funcionamiento por oído (indicación
de fecha/ora/modo de funcionamiento para cada medición).
7. Indicación de hora.
8. Función de cambio °C / °F.
9. Batería, 1 batería de litio (1 pz. CR2032).
10. Desconexión automática.
11. Puede realizarse la medición en el oído, el dispositivo calcula el valor correspondiente
que se derivaría de una medición oral.
0197
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eks Infrared Thermometer 0610 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eks Infrared Thermometer 0610 in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 4,27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info