Attention! Lisez le mode d’emploi!
Données techniques
FR
Touche Scan
Pointe de mesure
Objectif
Le bouchon protecteur
Ecran LCD
ON/MEM (Actif/Mémoire)
Mémoire
Chronomètre
Battery
Température
auriculaire
Scan
Température
ambiante
Temps/date
1. Portée mesure de température :
Mesures dans la “zone frontale ou auriculaire” : 34~42.2°C (93.2~108°F),
Prise de mesure : -22~80°C (-7.6~176°F).
2. Température de fonctionnement : 10~40°C (50~104°F).
3. Température de stockage : -20~50°C (-4~122°F), humidité relative ≤85%.
La température lors du transport doit être inférieure à 70°C, humidité relative ≤95%.
4. En conformité avec ASTM E1965-98, EN12470-5:2003 Thermomètres cliniques
Sortie des Thermomètresauriculaires infrarouges (valeurs maximales),
IEC/EN60601-1-2(EMC), IEC/EN60601-1 Instructions de sécurité.
5. Déviations
Avec mesure auriculaire : +/-0.2°C (0.4°F) dans la zone 35.5~42°C (95.9~107.6°F),
+/-0.3°C (0.5°F) hors de cette zone.
En mode Scan +/-0.3°C (0.5°F) dans la zone de 22~42.2°C (71.6~108°F),
+/-4% ou +/-2°C (4°F) hors de cette zone. La valeur supérieure est déterminante.
6. Positions de sauvegarde Alarme Fièvre pour utilisation auriculaire (achage de la date/
heure/mode d’opération pour chaque mesure).
7. Achage de l’heure.
8. Fonction changement °C / °F.
9. Batterie, 1 pile Lithium (CR2032 1 pc.)
10. Déconnexion automatique
11. Mesure auriculaire possible, l’appareil va calculer la valeur correspondante obtenue
avec une mesure buccale.
Ce produit est conforme aux dispositions de la directive européenne
93/42/EEC (Directive sur les produits médicaux).
Pièce d’application type BF
Pour éliminer l’appareil, conformez-vous à la directive sur les appareils
électriques et électroniques 2002/96/CE-DEEE (Déchets des équipements
électriques et électroniques).
Fabrication conforme aux normes internationales
Ces spécications peuvent être modiées sans avis préalable.
0197
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eks Infrared Thermometer 0610 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eks Infrared Thermometer 0610 in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 4,27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info