USER INSTRUCTIONS
IGNITION
With the boiler in stand-by mode, (after having
checked that
the chamber is clean), press the key
, and the
ignition procedure will start.
On the display
the wording
ON AC” (start combus-
tion) will appear; after certain control cycles and after
checking that the pellets are burning, the display will
show
the wording
ON AR” (heating on).
This phase will last a few minutes, to allow the ignition
procedure to complete correctly and for the exchang-
ers in the boiler to heat up.
After a few minutes, the boiler will enter the heating
phase, indicating
the wording
burn” and later, during
regular functioning, the temperature of the output wa-
ter, set by the user, is indicated and the power chosen
by the automatic modulation system.
SWITCHING OFF
Pressing the key , when the boiler is on, will start
the switching o phase, which involves:
• Stopping the delivery of the pellets
• Burning any pellets left in the chamber, keeping the
fume fan on (usually for about 10’)
• Cooling the boiler’s body while the pump remains on
until the shut-o temperature is reached
• The indication “OF” on the display together with the
minutes remaining until shut-o
During the switching o phase, the boiler cannot be
turned on again; when the switching o phase is
completed the system automatically goes into stand-
by mode.
AUTOMATIC FUNCTIONING
The user must set the output water temperature,
which must be assessed according to the type and
dimensions of the system, and considering the atmos-
pheric temperature linked to the season.
The boiler automatically modulates power according
to the di erence between the set temperature (set on
the display) and the temperature measured by the
water sensor; on reaching the desired temperature,
the burner will function at minimum, going to power
level 1.
The output water temperature can be increased by
pressing the
key
,
or decreased by pressing the key .
The display alternatively shows the desired tempera-
ture and the power which is automatically chosen by
the electronic modulating system.
ECONOMY FUNCTION
Function suitable for boilers installed in small-scale
systems, or whenever minimum power operation
causes excessive heating.
This function, managed automatically, allows for
switching the boiler o once the set delivery tempera-
ture is exceeded.
When the delivery temperature falls below the set val-
ue, the boiler switches back on automatically. Request
activation of this function, if required, from the Techni-
cal Assistance Centre during initial start-up.
When the ECONOMY function is activated, the display
will visualise ‘Econ’ after the other information.
REMOTE ACTIVATION FUNCTION
By means of a special connection wire (code 640560),
the boiler can be switched on/o by a remote control
device such as a GSM telephonic activator, an envi-
ronment thermostat, a zone valve, or in any case a
device with clean contact with the following logic:
Contact open = boiler o
Contact closed = boiler on
Activation and deactivation takes place 10” after the
transfer of the last command.
If the remote activation of the door is connected, the
boiler can be switched on and o in any case by the
control panel; the boiler will always act according to
the last command received, whether for switching on
or o .
PLEASE NOTE:
If the remote activation function is used, decouple the
remote connection cable, using a relay, if the distance
between the remote device and the boiler exceeds the
length of the cable code 640560 (1.5 m).
Consult the instruction sheet of the connection cable
for more detailed information.
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for EK63-EdilKamin Kappa at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of EK63-EdilKamin Kappa in the language / languages: English as an attachment in your email.

The manual is 1.39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of EK63-EdilKamin Kappa

EK63-EdilKamin Kappa Usermanual and installation guide - German - 28 pages

EK63-EdilKamin Kappa Usermanual and installation guide - French - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info