810964
29
Zoom out
Zoom in
Previous page
1/48
Next page
29
8. INSTALLATION
INSTALLER
8.1. Preliminary remarks on installation
Remember that:
The installation must be performed by qualified personnel;
All local and national laws and European Standards must be complied with when installing and using the product.
In Italy the reference is the standard UNI 10683;
In the case of installation in condominiums it is necessary an offer with positive recommendation of the
administrator;
In the case of installation in public places, check and comply with local regulations for these installations.
The product is designed to operate in all weather conditions. In case of special conditions, as strong wind, safety
systems may intervene forcing the switch off of the product. (if any)
Some indications of a general nature are given below, which do not replace the checking against the local standards
and do not bring any liability concerning the installer’s work.
8.2. Checking the suitability of the installation room
The volume of the room must be greater than that indicated in the technical table
The floor must be able to support the weight of the product and its accessories* (see the note in the paragraph
on heat protection)
Make sure that the product is levelled
Do not install in rooms where there is a risk of fire or explosion.
In Italy, check compatibility pursuant to UNI 10683 and UNI 7129 in the presence of gas products.
8.3. Heat protection and safety distances
All the surfaces of the building adjacent to the product must be protected against overheating.
The insulation measures to be taken depend on the type of surfaces present.
The product must be installed in accordance with the following safety conditions:
Minimum distance from any combustible materials: see the declaration of performance on the website
In the case of installation with a wall made of wood or other flammable material, the smoke exhaust pipe must be
adequately insulated.
The diameter of the smoke outlet is not the diameter of the chimney system. The chimney
system must be sized according to national and local regulations.
In particular, (non-exhaustive list) refer to EN 13384, EN 1443, EN 1856, EN 1457 and to all local
regulations.
Avoid the infiltration of condensation water through the chimney flue. If necessary, install an
anti-condensation ring - ask your chimney sweep.
Damage caused by condensation water is not covered by the warranty.
In some countries, in special conditions, multiple chimney flue installations are allowed.
According to regional regulations, additional safety systems are required when connecting to
multiple chimney flues. Your chimney sweep/technician is available for further information.
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for EK63-EdilKamin Fancy at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of EK63-EdilKamin Fancy in the language / languages: English as an attachment in your email.

The manual is 3.09 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of EK63-EdilKamin Fancy

EK63-EdilKamin Fancy Usermanual and installation guide - German - 48 pages

EK63-EdilKamin Fancy Usermanual and installation guide - Dutch - 48 pages

EK63-EdilKamin Fancy Usermanual and installation guide - French - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info